Introduction

The table below is an overview of the main connectors involved when installing the STENTOFON IP Heavy Duty stations.

Note! To access these connectors the frontplate must be removed
LAN 10/100 Mbps RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
AUX 10/100 Mbps RJ-45 ports for auxiliary equipment such as PC and IP camera.
Input/Output Pluggable screw terminal
Local Power Plugable screw terminal, 19-27 VDC Idle 4W, max. 8W

Power Supply

The IP Heavy Duty Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.

If PoE is not available, the IP Substation can be connected to a 24 VDC local power supply.

Network Connection

There are two RJ45 ports on the IP Heavy Duty stations:

  • LAN port (P1): for connecting to the network and the AlphaCom XE Audio Server.
  • AUX port (P2): for connecting to auxiliary equipment such as a PC or IP Camera.

Input/Output Connections

There are I/O connection options for all IP Substations. These I/O connections include:

  • 3 digital inputs (P4):
Input 1 = PTT from headset, and for restoring factory default
Input 2 = Call button no.2 or logical input (optional)
Input 3 = Hookswitch
  • 1 relay output (P3)
  • 1 logical output (TP9)
  • 1 Line out (TP1/2): Audio output to handset speaker (0dBm 600ohm balanced)