Main connectors
To access these connectors the frontplate must be removed.
LAN | 10/100 Mbps RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line. |
AUX | 10/100 Mbps RJ-45 ports for auxiliary equipment such as PC and IP camera. |
Input/Output | Pluggable screw terminal |
Local Power | Plugable screw terminal, 19-27 VDC Idle 4W, max. 8W |
Power Supply
The IP Heavy Duty Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.
If PoE is not available, the IP Substation can be connected to a 24 VDC local power supply.
Network Connection
There are two RJ45 ports on the IP Heavy Duty stations:
- LAN port (P1): for connecting to the network and the AlphaCom XE Audio Server.
- AUX port (P2): for connecting to auxiliary equipment such as a PC or IP Camera.
Input/Output Connections
There are I/O connection options for all IP Substations. These I/O connections include:
- 3 digital inputs (P4):
- Input 1 = PTT from headset, and for restoring factory default
- Input 2 = Call button no.2 or logical input (optional)
- Input 3 = Hookswitch
- 1 relay output (P3)
- 1 logical output (TP9)
- 1 Line out (TP1/2): Audio output to handset speaker (0dBm 600ohm balanced)
For more details see INCA Substation Board Connectors.