Difference between revisions of "INCA Hotline station Restore Factory Defaults"
From Zenitel Wiki
Line 1: | Line 1: | ||
{{APS}} | {{APS}} | ||
This procedure is applicable for the [[IP Hotline Station - 1008070000|IP Hotline Station]]. | This procedure is applicable for the [[IP Hotline Station - 1008070000|IP Hotline Station]]. | ||
+ | |||
'''Procedure:'''<br> | '''Procedure:'''<br> | ||
This procedure will load factory defalt settings in the station. The unit can be set to use either '''Static IP''' or '''DHCP'''. | This procedure will load factory defalt settings in the station. The unit can be set to use either '''Static IP''' or '''DHCP'''. |
Revision as of 17:04, 20 March 2017
This procedure is applicable for the IP Hotline Station.
Procedure:
This procedure will load factory defalt settings in the station. The unit can be set to use either Static IP or DHCP.
- While pressing the emergency button, power up the station and keep the button pressed.
- Release the button after exactly 2 flashes of the LED.
- Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
- Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
- Release the button and the station will restart with the factory default settings.
Factory default values:
- Station Mode: Pulse
- Station IP address: 169.254.1.100 (Static) or DHCP
- Username: admin
- Password: alphaadmin
It may be desired to reset an IP Hotline Station to its original settings if, for instance, the password for the web server is forgotten.
The defaults can be either be set to Static IP or Activated DHCP (when there are many new IP Substations in an installation).
Restore with Static IP
- While lifting the handset, power up the station.
- When the station LED starts blinking, replace the handset after exactly 2 blinks.
- Let the LED blink for exactly 2 more times, then lift the handset again.
- Keep the handset lifted until the LED blinks fast 2 times indicating a successful reset with static IP.
- Replace the handset and the station will restart with the factory default settings.
Factory default values | |
---|---|
Station Mode | Pulse |
Station IP address | 169.254.1.100 |
AlphaCom IP address | 169.254.1.5 |
Username* | admin |
Password* | alphaadmin |
* Software 01.06 and earlier: ADMIN/alphacom)
Restore with Activated DHCP
The DHCP option is available from software version 01.07.
- While lifting the handset, power up the station.
- When the station LED starts blinking, replace the handset after exactly 2 blinks.
- Let the LED blink for exactly 4 more times, then lift the handset again.
- Keep the handset lifted until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
- Replace the handset and the station will restart with the factory default settings.
Factory default values | |
---|---|
Station Mode | Pulse |
Station IP address | determined by DHCP server |
AlphaCom IP address | 169.254.1.5 |
Username* | admin |
Password* | alphaadmin |
* Software 01.06 and earlier: ADMIN/alphacom)