Difference between revisions of "IP School Intercom Station Restore Factory Defaults"
From Zenitel Wiki
Line 4: | Line 4: | ||
'''Procedure:'''<br> | '''Procedure:'''<br> | ||
When loading factory defalt settings, the unit can be set to use either '''Static IP''' or '''DHCP'''. | When loading factory defalt settings, the unit can be set to use either '''Static IP''' or '''DHCP'''. | ||
− | |||
− | |||
# While pressing the call button, power up the station and keep the button pressed. | # While pressing the call button, power up the station and keep the button pressed. | ||
# Release the button '''after exactly 2 flashes''' of the LED. | # Release the button '''after exactly 2 flashes''' of the LED. |
Revision as of 13:16, 20 March 2017
This procedure is applicable for the IP School Intercom Station.
Procedure:
When loading factory defalt settings, the unit can be set to use either Static IP or DHCP.
- While pressing the call button, power up the station and keep the button pressed.
- Release the button after exactly 2 flashes of the LED.
- Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
- Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
- Release the button and the station will restart with the factory default settings.
Factory default values:
- Station Mode: Pulse
- Station IP address: 169.254.1.100 (Static) or DHCP
- Username: admin
- Password: alphaadmin
* Software 01.06 and earlier: Username/password is ADMIN/alphacom
An IP Station may have to be reset to its original factory default settings if, for instance, the password to the webserver is forgotten.
The defaults can be either be set to Static IP or Activated DHCP.
This procedure is the recommended procedure for the IP School Intercom Station.
The Factory Default procedure can be used to either set the station to use a Static IP address, or to use IP address from a DHCP server.
Restore with Static IP
- While pressing the emergency call button, power up the station.
- When the station green LED starts blinking, release the emergency call button after exactly 2 blinks.
- Let the LED blink for exactly 2 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
- Release the button and the substation will restart with the factory default settings.
Factory default values | |
---|---|
Station Mode | Pulse |
Station IP address | 169.254.1.100 |
AlphaCom IP address | 169.254.1.5 |
Username* | admin |
Password* | alphaadmin |
* Software 01.06 and earlier: ADMIN/alphacom)
Restore with Activated DHCP
The DHCP option is available from software version 01.07.
- While pressing the emergency call button, power up the station.
- When the station green LED starts blinking, release the emergency call button after exactly 2 blinks.
- Let the LED blink for exactly 4 more times, then press the button again.
- Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
- Release the button and the station will restart with the factory default settings.
Factory default values | |
---|---|
Station Mode | Pulse |
Station IP address | determined by DHCP server |
AlphaCom IP address | 169.254.1.5 |
Username* | admin |
Password* | alphaadmin |
* Software 01.06 and earlier: ADMIN/alphacom)