Actions

Difference between revisions of "Billing Installation Guide"

From Zenitel Wiki

 
(70 intermediate revisions by 6 users not shown)
Line 1: Line 1:
If you are running on the new file system (AMC Board Support Package Version 10.00), then you can just upgrade with the billing package 1.00 (alpha_billing_01_00.tbz2).
+
{{A}}
To install new file system on the Alphacom, follow the instructions below:
+
Billing version 2 is only supported on Alphacom XE platform and requires the [[Board_Support_Package | board support package ]] version 30.00 of the AMC IP Card. <br>
  
1. Install "Alphacom Image Upgrade" application on your computer (Requires .NET Framework 3.0)
+
[[Image:Frontpage_billing.jpg|thumb|right|500px|Billing web Status page]]
  
2. Copy the image "alpha_uimage_20_billing.bin" (or desired image) to Server root catalog selected while installing the program (for example: C:\Program Files\STENTOFON\AlphaImageUpgrade\ServerRoot)
+
If you already are running the APKG package alpha-sys-11.1.3.1.apkg or later on the [[AMC-IP_-_AlphaCom_Processor_Board_(Black)|new AMC IP Card]], billing can be activated by inserting a new license included billing trunks.
  
3. Install the Alphasyspackage "alpha_sys_10_52.tbz2" (In order to install this package, alpha_sys_10_51.tbz2 should be already installed)
+
For new purchased AMC IP Card, please proceed with steps explained:
  
4. If it exist newer Billing package version you want to install, do it before configuring the billing system. (alpha_billing_01_10.tbz2 is the latest release by 01.03.2009)
+
Steps in short:
 +
* Perform a "GET ALL" with the minimum version AlphaPro v11.00 from the old AMC IP card
 +
* Flash latest image on the AMC IP Card
 +
* Insert the new license including billing
 +
* Install the latest APKG package
 +
* Restore the AlphaPro database
 +
* Enable the Billing Node Exchange in AlphaPro in netrouting for SIP node
 +
* Copy the billing version 1 into to filesystem using WinSCP
  
5. Insert a license key with desired SIP Trunk Lines
+
<br style="clear:both;" />
  
6. Enable the Billing Node Exchange under "NET Rounting/AlphaNet Routing/General Settings/Billing Node"
 
  
7. Send Changes and reset in the AlphaPro to update database configuration in the Billing Web interface.
+
 
 +
== To install or upgrade from the billing version 1 to 2, follow the instructions below  ==
 +
 
 +
<br style="clear:both;" />
 +
 
 +
=== Perform a "Get ALL" with minimum AlphaPro ver 11.00 to Backup the AlphaPro Database from the old AMC IP Card ===
 +
[[Image:Get_all_AlphaPro.png|thumb|350px|AlphaPro]]
 +
 
 +
<br style="clear:both;" />
 +
 
 +
=== Flash the latest image with support for BSP 30.00  with Alpha Image Upgrade Application ===
 +
 
 +
[[Image:Flash_image_upgrade_application.jpg|thumb|350px|Alpha Image Upgrade application]]
 +
Install the latest image (Current image: axeu_b3000_a1100300.aimg) with Alpha Image Upgrade Application.<br>
 +
For detailed description: [[AMC_Flash_Image_update | AMC Flash Image update]]
 +
 
 +
<br style="clear:both;" />
 +
 
 +
=== Install the latest APKG package 11.xx on the Alphacom ===
 +
 
 +
[[Image:install_APKG_package.jpg|thumb|350px|Alpha Web]]
 +
Install the latest image (Currenct package: alpha-sys-11.1.3.1.apkg) with Alpha Image Upgrade Application.<br>
 +
 
 +
<br style="clear:both;" />
 +
 
 +
 
 +
===Insert a license key with desired Billing trunks===
 +
[[Image:Iicense.jpg|thumb|350px|AlphaWeb license Page]]
 +
 
 +
The Billing license packages are:
 +
 
 +
*100 9647 902: 2 simultaneous out-going Billing calls
 +
*100 9647 904: 4 simultaneous out-going Billing calls
 +
*100 9647 908: 8 simultaneous out-going Billing calls
 +
*100 9647 916: 16 simultaneous out-going Billing calls
 +
*100 9647 932: 32 simultaneous out-going Billing calls
 +
 
 +
<br style="clear:both;" />
 +
 
 +
=== Copy the billing version 1 database file to location: /opt/backup/db ===
 +
 
 +
[[Image:WinSCP.jpg|thumb|350px|WinSCP]]
 +
Copy the “acm.db” or/and "calllogs.db" directory to opt/backup/db from your computer.<br>
 +
 
 +
Connect to Alphacom by WinSCP using SFTP (port 22):
 +
 
 +
Default:
 +
*Login:  root
 +
*Password: {root-password}
 +
 
 +
 
 +
This tool can be downloaded at
 +
 
 +
[http://winscp.net/eng/download.php | http://winscp.net/eng/download.php]
 +
 
 +
<br style="clear:both;" />
 +
 
 +
[[Image:upgradedatabase.jpg|thumb|350px|BillingWeb Database upgrade]]
 +
 
 +
Log out/inn on the billing web and enter "UPGRADE" to upgrade the database.
 +
 
 +
Note!A default Trunk access group will be made, and all the users and extension will be member of that group.
 +
<br style="clear:both;" />
 +
 
 +
=== Perform a "Send ALL" with minimum AlphaPro ver 11.00 to restore the AlphaPro Database ===
 +
[[Image:Alphanet_netrouting.jpg|thumb|350px|AlphaNet Routing]]
 +
 
 +
Remember to Enable the billing node in alphaNet routing to SIP Nodes to be controlled by billing.
 +
If you want just some of the trunks towards a SIP Node to activate billing on, make a new SIP Node with same address, and attach the trunks against the SIP Node
 +
 
 +
Note! If you already are running the APKG package alpha-sys-11.1.3.1.apkg or later, billing can be activated only by insert a new license and completeing this last step.
 +
 
 +
 
 +
[[Category:Billing]]
 +
[[Category:AlphaCom - SIP Integration]]

Latest revision as of 15:07, 13 March 2018

AlphaCom icon 300px.png

Billing version 2 is only supported on Alphacom XE platform and requires the board support package version 30.00 of the AMC IP Card.

Billing web Status page

If you already are running the APKG package alpha-sys-11.1.3.1.apkg or later on the new AMC IP Card, billing can be activated by inserting a new license included billing trunks.

For new purchased AMC IP Card, please proceed with steps explained:

Steps in short:

  • Perform a "GET ALL" with the minimum version AlphaPro v11.00 from the old AMC IP card
  • Flash latest image on the AMC IP Card
  • Insert the new license including billing
  • Install the latest APKG package
  • Restore the AlphaPro database
  • Enable the Billing Node Exchange in AlphaPro in netrouting for SIP node
  • Copy the billing version 1 into to filesystem using WinSCP



To install or upgrade from the billing version 1 to 2, follow the instructions below


Perform a "Get ALL" with minimum AlphaPro ver 11.00 to Backup the AlphaPro Database from the old AMC IP Card

AlphaPro


Flash the latest image with support for BSP 30.00 with Alpha Image Upgrade Application

Alpha Image Upgrade application

Install the latest image (Current image: axeu_b3000_a1100300.aimg) with Alpha Image Upgrade Application.
For detailed description: AMC Flash Image update


Install the latest APKG package 11.xx on the Alphacom

Alpha Web

Install the latest image (Currenct package: alpha-sys-11.1.3.1.apkg) with Alpha Image Upgrade Application.



Insert a license key with desired Billing trunks

AlphaWeb license Page

The Billing license packages are:

  • 100 9647 902: 2 simultaneous out-going Billing calls
  • 100 9647 904: 4 simultaneous out-going Billing calls
  • 100 9647 908: 8 simultaneous out-going Billing calls
  • 100 9647 916: 16 simultaneous out-going Billing calls
  • 100 9647 932: 32 simultaneous out-going Billing calls


Copy the billing version 1 database file to location: /opt/backup/db

WinSCP

Copy the “acm.db” or/and "calllogs.db" directory to opt/backup/db from your computer.

Connect to Alphacom by WinSCP using SFTP (port 22):

Default:

  • Login: root
  • Password: {root-password}


This tool can be downloaded at

| http://winscp.net/eng/download.php


BillingWeb Database upgrade

Log out/inn on the billing web and enter "UPGRADE" to upgrade the database.

Note!A default Trunk access group will be made, and all the users and extension will be member of that group.

Perform a "Send ALL" with minimum AlphaPro ver 11.00 to restore the AlphaPro Database

AlphaNet Routing

Remember to Enable the billing node in alphaNet routing to SIP Nodes to be controlled by billing. If you want just some of the trunks towards a SIP Node to activate billing on, make a new SIP Node with same address, and attach the trunks against the SIP Node

Note! If you already are running the APKG package alpha-sys-11.1.3.1.apkg or later, billing can be activated only by insert a new license and completeing this last step.