== Single Tone Signaling== | == Single Tone Signaling== | ||
− | 20 unique tones | + | 20 unique tones |
− | + | 0-9 are sinus tones in the range 500Hz to 2300 Hz, 200 Hz steps | |
+ | 10-19 are sinus tones in the range 600Hz to 2400 Hz, 200 Hz steps | ||
== Two Tone == | == Two Tone == |
Revision as of 09:28, 10 May 2007
Signalig protocol
To types of signaling protocols used towards the stations
Current Signaling
Single Tone Signaling
20 unique tones 0-9 are sinus tones in the range 500Hz to 2300 Hz, 200 Hz steps 10-19 are sinus tones in the range 600Hz to 2400 Hz, 200 Hz steps
Two Tone
- Key board digit 0-9
- Digit Tone 0-9
- DAK D1-D15
- Digit tone 10 + 0 to 10 + 14
- DAK D16-D30
- Digit tone 11 + 0 to 11 + 14
- DAK D31-D45
- Digit tone 12 + 0 to 12 + 14
- DAK D46-D60
- Digit tone 13 + 0 to 13 + 14
- DAK D61-D75
- Digit tone 14 + 0 to 14 + 14
- DAK D76-D90
- Digit tone 15 + 0 to 15 + 14
- DAK D91-D100
- Digit tone 16 + 0 to 15 + 9
Optional DAK Acknowledge
If the station is configured with acknowledge on DAK keys:
- The AMC application will send an acknowledge message by the Display Text Protocol.
- The station will acknowled this by sending tone 18.