Difference between revisions of "Serial port pinout"
From Zenitel Wiki
Line 17: | Line 17: | ||
|} | |} | ||
<br\><br\> | <br\><br\> | ||
− | Cabling between RIO unit and AlphaCom E using multidrop RS485: | + | Cabling between [[RIO]] unit and AlphaCom E using multidrop RS485: |
{|border="1" | {|border="1" | ||
|- | |- |
Revision as of 11:33, 17 August 2007
In the AlphaCom E20 and E26 the two serial ports are available on RJ45 connectors. In the AlphaCom E7 serial port 0 is 9 pin DSUB, and serial poret 1 is RJ45.
The serial port 0 can be RS232 only, the serial port 1 can be RS232, RS422 or RS485.
The pinout on the RJ45 connector is as follows:
RJ45 pinout | |
---|---|
RS232 | 3 = TX<br\>6 = RX<br\> 4&5 = GND |
RS422 | 1 = RX-<br\>2 = RX+<br\>7 = TX-<br\>8 = TX+ |
RS485 | 1/7 = Data - <br\> 2/8 = Data+ |
<br\><br\> Cabling between RIO unit and AlphaCom E using multidrop RS485:
RJ45 - AlphaCom E | RIO 15 p DSUB |
---|---|
1 (RX-) | 9 (TX+) |
2 (RX+) | 2 (TX-) |
7 (TX+) | 11 (RX+) |
8 (TX+) | 4 (RX-) |