Difference between revisions of "TCAS Connections"
From Zenitel Wiki
(→Second Call Button) |
|||
(19 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | [[File:TCAS Connections 1.PNG| | + | {{A}} |
− | This article | + | [[File:TCAS Connections 1.PNG|thumb|right500px|TCAS substation - Rear side]] |
+ | This article describes connection details of the analog intercoms [[TCAS-1]], [[TCAS-2]] and [[TCAS-3]]. | ||
− | The | + | ==Wiring== |
+ | The cabling from the AlphaCom server to the intercom station is star wiring. Two twisted pairs of wires are required. The maximum distance depends on the cable diameter: | ||
+ | * 0.5 mm wires: 1.4 km | ||
+ | * 0.6 mm wires: 2.0 km | ||
+ | * 0.9 mm wires: 4.0 km | ||
− | + | The station line can be connected in to ways: | |
− | + | * By means of an RJ45 connector at the rear side of the station, or | |
− | + | * By using the plugable screw connector | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | Connection using the RJ45 connector: | |
+ | [[File:WiringAnalogTCAS.png|thumb|left|800px]] | ||
+ | <br style="clear:both;" /> | ||
− | + | {{note| The [[Station cable for 4 wire analogue station|station cable]] is not a 1:1 cable! }} | |
− | + | ||
− | + | For details on connection at the AlphaCom server side, see [[ASLT - AlphaCom Subscriber Line Board]] | |
− | |||
− | + | <br> | |
− | |||
− | + | == Second Call Button == | |
+ | The station is prepared for a second external call button (DAK 2). The button can be connected between the A-wire and the lower leg on D6 on the print (highlighted in the image above). | ||
[[File:TCAS Connections 2.PNG|thumb|left|500px]] | [[File:TCAS Connections 2.PNG|thumb|left|500px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | |||
− | [[Category: Turbine]] | + | [[Category: Turbine Connections]] |
Latest revision as of 11:51, 31 August 2018
This article describes connection details of the analog intercoms TCAS-1, TCAS-2 and TCAS-3.
Wiring
The cabling from the AlphaCom server to the intercom station is star wiring. Two twisted pairs of wires are required. The maximum distance depends on the cable diameter:
- 0.5 mm wires: 1.4 km
- 0.6 mm wires: 2.0 km
- 0.9 mm wires: 4.0 km
The station line can be connected in to ways:
- By means of an RJ45 connector at the rear side of the station, or
- By using the plugable screw connector
Connection using the RJ45 connector:
The station cable is not a 1:1 cable! |
For details on connection at the AlphaCom server side, see ASLT - AlphaCom Subscriber Line Board
Second Call Button