Difference between revisions of "TCAS Connections"
From Zenitel Wiki
(→Second Call Button) |
|||
Line 24: | Line 24: | ||
== Second Call Button == | == Second Call Button == | ||
− | The station is prepared for a second external call button (DAK 2). The button can be connected between the A-wire and the lower leg on D6 (highlighted in the image above) | + | The station is prepared for a second external call button (DAK 2). The button can be connected between the A-wire and the lower leg on D6 on the print (highlighted in the image above). |
[[File:TCAS Connections 2.PNG|thumb|left|500px]] | [[File:TCAS Connections 2.PNG|thumb|left|500px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
[[Category: Turbine Connections]] | [[Category: Turbine Connections]] |
Latest revision as of 11:51, 31 August 2018
This article describes connection details of the analog intercoms TCAS-1, TCAS-2 and TCAS-3.
Wiring
The cabling from the AlphaCom server to the intercom station is star wiring. Two twisted pairs of wires are required. The maximum distance depends on the cable diameter:
- 0.5 mm wires: 1.4 km
- 0.6 mm wires: 2.0 km
- 0.9 mm wires: 4.0 km
The station line can be connected in to ways:
- By means of an RJ45 connector at the rear side of the station, or
- By using the plugable screw connector
Connection using the RJ45 connector:
The station cable is not a 1:1 cable! |
For details on connection at the AlphaCom server side, see ASLT - AlphaCom Subscriber Line Board
Second Call Button
The station is prepared for a second external call button (DAK 2). The button can be connected between the A-wire and the lower leg on D6 on the print (highlighted in the image above).