Actions

Difference between revisions of "Delayed Reporting of Line Errors"

From Zenitel Wiki

(Disable default Line Error reporting)
(Disable reporting to System Log)
Line 15: Line 15:
  
 
=== Disable reporting to System Log ===
 
=== Disable reporting to System Log ===
Station errors are by default sent to the [[System Log]]. From AlphaPro one can disable this reporting.
+
Station errors are by default sent to the [[System log]]. From AlphaPro one can disable this reporting.

Revision as of 15:51, 15 November 2018

AlphaCom icon 300px.png

By default station errors are reported more or less instantly when the AlphaCom server looses connection to an IP Station, or if there is an error on the analog ASLT station line.

Sometimes it could be convenient to delay the reporting, for example if there is maintenance work in the IP network, repatching of cables etc.

This article describes how to disable the default reporting, and how to use customized error reporting using the Event Handler instead.

Disable default Line Error reporting

Reporting to station

Station errors are by default sent to station on physical number 1. From AlphaPro one can disable this reporting.

Go to the Exchange & System > RCI > Faults window, select Fault Line > Change, and delete the MST command in the ON Action field.

The Exchange & System > RCI > Faults window

Disable reporting to System Log

Station errors are by default sent to the System log. From AlphaPro one can disable this reporting.