Difference between revisions of "Physical number 5 and 6 (AlphaCom E7)"
From Zenitel Wiki
Line 1: | Line 1: | ||
− | In the [[AlphaCom XE7]] the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default. The potmeters P5 and P6 are used to adjust the input level. Line points 5 and 6 can also be used as normal subscriber points. | + | In the [[AlphaCom XE7]] the physical numbers 5 and 6 on the first [[ASLT|ASLT line board]] are enabled for program distribution by default. The potmeters P5 and P6 are used to adjust the input level. Line points 5 and 6 can also be used as normal subscriber points. |
* To enable physical number 5 and/or 6 to be used for regular intercom stations: | * To enable physical number 5 and/or 6 to be used for regular intercom stations: |
Revision as of 16:38, 1 March 2019
In the AlphaCom XE7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default. The potmeters P5 and P6 are used to adjust the input level. Line points 5 and 6 can also be used as normal subscriber points.
- To enable physical number 5 and/or 6 to be used for regular intercom stations:
- Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
- In AlphaPro, select Exchange & System -> Boards
- Change the port setting from ‘Audio program feed’ to ‘Default’
- Reset the exchange