Difference between revisions of "Advancis WinGuard"
From Zenitel Wiki
(→AlphaPro) |
(→AlphaPro) |
||
Line 6: | Line 6: | ||
===AlphaPro=== | ===AlphaPro=== | ||
Configure the ACDP port to be used towards WinGuard: | Configure the ACDP port to be used towards WinGuard: | ||
− | + | [[File:WinGuard SerialPort.PNG|thumb|500px|Serial Port settings for WinGuard]] | |
From the AlphaPro main menu, select [[Exchange_%26_System_(AlphaPro)#Serial_Ports|Exchange & System > Serial Ports]], and select one of the available ACDP links and program as follows: | From the AlphaPro main menu, select [[Exchange_%26_System_(AlphaPro)#Serial_Ports|Exchange & System > Serial Ports]], and select one of the available ACDP links and program as follows: | ||
* Port Type: TCP/IP server | * Port Type: TCP/IP server |
Revision as of 13:02, 26 March 2019
General
WinGuard is the PSIM software from Advancis. Integration between WinGuard and AlphaCom is via the Simple Link Layer protocol. The following paragraphs give a short setup guide of the system, for more details please contact Advancis directly.
AlphaCom Setup
AlphaPro
Configure the ACDP port to be used towards WinGuard:
From the AlphaPro main menu, select Exchange & System > Serial Ports, and select one of the available ACDP links and program as follows:
- Port Type: TCP/IP server
- Link Type: Stentofon Simple Link Layer
- Broadcast: Enabled
- Port: Enter a TCP/IP port nr on which WinGuard and AlphaCom will communicate, default for WinGuard is 4001
- Keep Alive: Enabled
AlphaWeb
Make certain that the TCP/IP port as selected above is defined and enabled in the 'Filter-page' in AlphaWeb.