Revision as of 08:35, 12 April 2019
LEDs on Front Plate
- Power LED (Green): Steady light when power is OK
- Fault LED (Yellow): Flashing when the station is not registered/no connection to server
- Call LED (Red): Steady light during a conversation/call
Status LEDs on PCB
Flashing 2 red + 1 green:
- Station has no connection to the AlphaCom server/exchange.
Flashing 1 red + 2 green:
- Station connected but NOT registered in the AlphaCom server/exchange.
Flashing 3 green
- Station connected and registered in the AlphaCom server/exchange.
Ethernet Activity & Speed LEDs on PCB
Green LED:
- Steady light: Ethernet connection OK
- Flashing: Ethernet data traffic
- No light: No Ethernet connection
Yellow LED:
- Steady light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection