Actions

TFIE Indication LEDs: Difference between revisions

From Zenitel Wiki

Line 3: Line 3:
<br style="clear:both;" />
<br style="clear:both;" />


'''Power LED (Green):''' Steady light when power is OK
*'''Power LED (Green):''' Steady light when power is OK
'''Fault LED (Yellow):''' Flashing when the station is not registered/no connection to server
*'''Fault LED (Yellow):''' Flashing when the station is not registered/no connection to server
'''Call LED (Red):''' Steady light during a conversation/call
*'''Call LED (Red):''' Steady light during a conversation/call


==Status LEDs on PCB==
==Status LEDs on PCB==

Revision as of 08:35, 12 April 2019

LEDs on Front Plate

TFIE Indications 1.PNG


  • Power LED (Green): Steady light when power is OK
  • Fault LED (Yellow): Flashing when the station is not registered/no connection to server
  • Call LED (Red): Steady light during a conversation/call

Status LEDs on PCB

TFIE Board Indications 1.png


Flashing 2 red + 1 green:

  • Station has no connection to the AlphaCom server/exchange.

Flashing 1 red + 2 green:

  • Station connected but NOT registered in the AlphaCom server/exchange.

Flashing 3 green

  • Station connected and registered in the AlphaCom server/exchange.

Ethernet Activity & Speed LEDs on PCB

TFIE Board Indications 2.png


Green LED:

  • Steady light: Ethernet connection OK
  • Flashing: Ethernet data traffic
  • No light: No Ethernet connection

Yellow LED:

  • Steady light: 100 Mbit Ethernet connection
  • No light: 10 Mbit Ethernet connection
MediaWiki spam blocked by CleanTalk.