Difference between revisions of "TFIE Indication LEDs"
From Zenitel Wiki
(→Status LEDs on PCB) |
(→Status LEDs on PCB) |
||
Line 10: | Line 10: | ||
[[File:TFIE Board Indications 1.png|thumb|left|500px]] | [[File:TFIE Board Indications 1.png|thumb|left|500px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | *'''Flashing 2 red + 1 green:'' Station has no connection to the AlphaCom server/exchange. | + | *'''Flashing 2 red + 1 green:''' Station has no connection to the AlphaCom server/exchange. |
*'''Flashing 1 red + 2 green:''' Station connected but NOT registered in the AlphaCom server/exchange. | *'''Flashing 1 red + 2 green:''' Station connected but NOT registered in the AlphaCom server/exchange. | ||
*'''Flashing 3 green''' Station connected and registered in the AlphaCom server/exchange. | *'''Flashing 3 green''' Station connected and registered in the AlphaCom server/exchange. |
Revision as of 08:35, 12 April 2019
LEDs on Front Plate
- Power LED (Green): Steady light when power is OK
- Fault LED (Yellow): Flashing when the station is not registered/no connection to server
- Call LED (Red): Steady light during a conversation/call
Status LEDs on PCB
- Flashing 2 red + 1 green: Station has no connection to the AlphaCom server/exchange.
- Flashing 1 red + 2 green: Station connected but NOT registered in the AlphaCom server/exchange.
- Flashing 3 green Station connected and registered in the AlphaCom server/exchange.
Ethernet Activity & Speed LEDs on PCB
Green LED:
- Steady light: Ethernet connection OK
- Flashing: Ethernet data traffic
- No light: No Ethernet connection
Yellow LED:
- Steady light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection