Actions

Difference between revisions of "Relay Settings (SIP)"

From Zenitel Wiki

Line 21: Line 21:
 
*'''Outgoing Ringing / Incoming Ringing''': Operate the relay while the station is ringing due to an incoming or outgoing call. The ringing state occurs from the call has started until the call has been accepted.
 
*'''Outgoing Ringing / Incoming Ringing''': Operate the relay while the station is ringing due to an incoming or outgoing call. The ringing state occurs from the call has started until the call has been accepted.
 
* '''Outgoing Call / Incoming Call''': Operate the relay while the station is in conversation.  The call state occurs from the call is accepted untill the cal ends.
 
* '''Outgoing Call / Incoming Call''': Operate the relay while the station is in conversation.  The call state occurs from the call is accepted untill the cal ends.
* '''Group Call (Pulse mode only)''': Operate the relay when the station receives a group call
+
* '''Group Call (Edge mode only)''': Operate the relay when the station receives a group call
 
* '''Idle''': Choose which state the relay should change to when nothing else is occuring on the station.
 
* '''Idle''': Choose which state the relay should change to when nothing else is occuring on the station.
 
* '''Error''': Choose which state the relay should change to when the station is off-line (not registered on any SIP server).
 
* '''Error''': Choose which state the relay should change to when the station is off-line (not registered on any SIP server).
  
 
=== Related articles ===
 
=== Related articles ===
* [[Web Call and HTTP commands (SIP/Pulse)|Controlling relay via Web Call and HTTP Commands]]
+
* [[Web Call and HTTP commands (Edge/SIP)|Controlling relay via Web Call and HTTP Commands]]
* [[Advanced Output Handler (Pulse/SIP)|Advanced Output Handler]]
+
* [[Advanced Output Handler (Edge/SIP)|Advanced Output Handler]]
  
 
[[Category: SIP intercom - Configuration]]
 
[[Category: SIP intercom - Configuration]]

Revision as of 12:12, 23 August 2019

PS.png

To configure relay operation, select SIP Configuration > Relay/Outputs.

Relay/Outputs


In Relay/Outputs you configure when a relay or output should change state. There are 4 different states: on, off, slow blinking and fast blinking. The "-" sign means that the behaviour does not change when the event occurs. The relay state can change either with a remote digit (DTMF signal) during a call, or if the station state changes.

Note icon As from Turbine firmware 4.11 you can choose between Basic Relay handling (in the image above), or Use Advanced Output Handler: The "Advanced Output Handler" makes it possible to better customize the relay/GPO handling to your preferences.


Choose Relay To Configure:

  • Select which relay or output to configure. The number of relays available depend on the device hardware.
  • Outputs will become available in the list after being configured as "Outputs" in the I/O Settings page.

Remote DTMF digit during call:

  • Remote Digit For Relay On/Off/Slow flash/Fast flash: Choose which remote digit (DTMF signal) should change the relay to the on/off/Slow flash/Fast flash state
  • Remote Digit For Relay Toggle: Toggles the relay on/off every time the specified DTMF digit is received
  • Remote Digit For Relay Timed Relay On: Choose which remote digit (DTMF signal) should change the relay to the on state for a configureable number of seconds. This state is normally used for Door Opening feature.

Change of station state:

  • Outgoing Ringing / Incoming Ringing: Operate the relay while the station is ringing due to an incoming or outgoing call. The ringing state occurs from the call has started until the call has been accepted.
  • Outgoing Call / Incoming Call: Operate the relay while the station is in conversation. The call state occurs from the call is accepted untill the cal ends.
  • Group Call (Edge mode only): Operate the relay when the station receives a group call
  • Idle: Choose which state the relay should change to when nothing else is occuring on the station.
  • Error: Choose which state the relay should change to when the station is off-line (not registered on any SIP server).