Difference between revisions of "Program station volume feature"
From Zenitel Wiki
(11 intermediate revisions by 5 users not shown) | |||
Line 1: | Line 1: | ||
+ | {{AI}} | ||
{| | {| | ||
|- | |- | ||
Line 13: | Line 14: | ||
|} | |} | ||
<br> | <br> | ||
− | The [[ASLT]] output level can also be set from the Users & Stations menu in [[AlphaPro]]. | + | The [[ASLT]] output level can also be set from the Users & Stations menu in [[AlphaPro]]. As from AMC ver. 11.2.3.x the relation between the 783 volume setting and AlphaPro setting is as follows: |
− | AlphaPro 783+n | + | $VOL / |
− | -------- ----- | + | AlphaPro 783+n IP-station DIP NVRAM |
− | -14 0 | + | -------- ----- ---------- --- ----- |
− | -12 | + | -14 0 1 0 242 |
− | -10 | + | -12 1 244 |
− | -8 1 | + | -10 1 246 |
− | -6 | + | -8 1 2 4 248 |
− | -4 2 | + | -6 2 250 |
− | -2 | + | -4 2 3 9 252 |
− | 0 3 | + | -2 3 254 |
− | 2 4 | + | 0 3 4 13 0 |
− | 4 5 | + | 2 4 4 2 |
− | 6 6 | + | 4 5 5 18 4 |
− | 8 7 | + | 6 6 5 6 |
− | 10 | + | 8 7 6 22 8 |
− | 12 8 | + | 10 6 10 |
− | 14 | + | 12 8 7 27 12 |
− | 16 9 | + | 14 7 14 |
+ | 16 9 8 31 16 | ||
− | [[AlphaNet Data Protocol|AlphaCom Data Protocol]] message | + | |
+ | Versions prior to AMC 11.2.3.x: | ||
+ | |||
+ | AlphaPro 783+n IP-station | ||
+ | -------- ----- ---------- | ||
+ | -14 0 | ||
+ | -12 1 | ||
+ | -10 | ||
+ | -8 1 2 | ||
+ | -6 | ||
+ | -4 2 3 | ||
+ | -2 | ||
+ | 0 3 4 | ||
+ | 2 4 | ||
+ | 4 5 5 | ||
+ | 6 6 | ||
+ | 8 7 6 | ||
+ | 10 | ||
+ | 12 8 7 | ||
+ | 14 | ||
+ | 16 9 8 | ||
+ | |||
+ | Related [[AlphaNet Data Protocol|AlphaCom Data Protocol]] message: [[VOLUME|VOL]] | ||
[[AlphaCom Feature List|Back to feature list]] | [[AlphaCom Feature List|Back to feature list]] |
Latest revision as of 08:45, 8 October 2019
Feature: | Set station volume |
Default directory number: | 783 |
Feature number: | 38 |
Parameter 1: | 0 (N/A) |
Description: | Set output level (0-9) on ASLT line board. Primarily to compensate for long wires. Dial: 783 + digit 0-9. Default level is 3. |
The ASLT output level can also be set from the Users & Stations menu in AlphaPro. As from AMC ver. 11.2.3.x the relation between the 783 volume setting and AlphaPro setting is as follows:
$VOL / AlphaPro 783+n IP-station DIP NVRAM -------- ----- ---------- --- ----- -14 0 1 0 242 -12 1 244 -10 1 246 -8 1 2 4 248 -6 2 250 -4 2 3 9 252 -2 3 254 0 3 4 13 0 2 4 4 2 4 5 5 18 4 6 6 5 6 8 7 6 22 8 10 6 10 12 8 7 27 12 14 7 14 16 9 8 31 16
Versions prior to AMC 11.2.3.x:
AlphaPro 783+n IP-station -------- ----- ---------- -14 0 -12 1 -10 -8 1 2 -6 -4 2 3 -2 0 3 4 2 4 4 5 5 6 6 8 7 6 10 12 8 7 14 16 9 8
Related AlphaCom Data Protocol message: VOL