Difference between revisions of "TCIS Indication LEDs"
From Zenitel Wiki
(→Status LEDs on PCB) |
|||
Line 35: | Line 35: | ||
[[File:TCIS Board Indications 1.png|thumb|300px|left]] | [[File:TCIS Board Indications 1.png|thumb|300px|left]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | '''Flashing 2 red + 1 green''' | + | *'''Flashing 2 red + 1 green''': Station has no connection to the AlphaCom server. |
− | + | *'''Flashing 1 red + 2 green''': Station connected but NOT registered in the AlphaCom server. | |
− | + | *'''Flashing 3 green''': Station connected and registered in the AlphaCom server. | |
− | '''Flashing 1 red + 2 green''' | ||
− | |||
− | |||
− | '''Flashing 3 green''' | ||
− | |||
=Ethernet Activity & Speed LEDs on PCB= | =Ethernet Activity & Speed LEDs on PCB= |
Revision as of 13:30, 10 December 2019
LEDs on Front Plate
Status LEDs
- - Bell icon lights yellow when a call is placed and ringing
- - Talk icon lights green when a call is active and in conversation
- - Door icon lights red when the door is unlocked or relay is active
Talk Icon: Flashing at 1 second intervals:
Station has no connection to the AlphaCom server/exchange.
Possible reasons:
- No connection to Ethernet
- Wrong AlphaCom XE IP address configured
- Invalid IP address
- No gateway or wrong gateway to the AlphaCom server/exchange
Talk Icon: Flashing at 5 second intervals:
Station connected but NOT registered in the AlphaCom server/exchange.
Reason:
- Station has not been programmed in AlphaPro
Status LEDs on PCB
- Flashing 2 red + 1 green: Station has no connection to the AlphaCom server.
- Flashing 1 red + 2 green: Station connected but NOT registered in the AlphaCom server.
- Flashing 3 green: Station connected and registered in the AlphaCom server.
Ethernet Activity & Speed LEDs on PCB
Green LED
- Steady light: Ethernet connection OK
- Flashing: Ethernet data traffic
- No light: No Ethernet connection
Yellow LED
- Steady light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection