Difference between revisions of "TCIS Indication LEDs"
From Zenitel Wiki
(→Status LEDs on PCB) |
(→LEDs on Front Plate) |
||
Line 2: | Line 2: | ||
=LEDs on Front Plate= | =LEDs on Front Plate= | ||
'''Status LEDs''' | '''Status LEDs''' | ||
− | + | * '''Bell icon''' lights '''yellow''' when a call is placed and ringing | |
− | + | * '''Talk icon''' lights '''green''' when a call is active and in conversation | |
− | + | * '''Door icon''' lights '''red''' when the door is unlocked or relay is active | |
[[File:TCIS Indications 1.PNG|thumb|300px|left]] | [[File:TCIS Indications 1.PNG|thumb|300px|left]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> |
Revision as of 13:31, 10 December 2019
LEDs on Front Plate
Status LEDs
- Bell icon lights yellow when a call is placed and ringing
- Talk icon lights green when a call is active and in conversation
- Door icon lights red when the door is unlocked or relay is active
Talk Icon: Flashing at 1 second intervals:
Station has no connection to the AlphaCom server/exchange.
Possible reasons:
- No connection to Ethernet
- Wrong AlphaCom XE IP address configured
- Invalid IP address
- No gateway or wrong gateway to the AlphaCom server/exchange
Talk Icon: Flashing at 5 second intervals:
Station connected but NOT registered in the AlphaCom server/exchange.
Reason:
- Station has not been programmed in AlphaPro
Status LEDs on PCB
- Flashing 2 red + 1 green: Station has no connection to the AlphaCom server.
- Flashing 1 red + 2 green: Station connected but NOT registered in the AlphaCom server.
- Flashing 3 green: Station connected and registered in the AlphaCom server.
Ethernet Activity & Speed LEDs on PCB
Green LED
- Steady light: Ethernet connection OK
- Flashing: Ethernet data traffic
- No light: No Ethernet connection
Yellow LED
- Steady light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection