=LEDs on Front Plate=
==LEDs on Front Panel==
'''Status LEDs'''
'''Status LEDs'''
* '''Bell icon''' lights '''yellow''' when a call is placed and ringing
* '''Bell icon''' lights '''yellow''' when a call is placed and ringing
Line 32: Line 32:
<br style="clear:both;" />
<br style="clear:both;" />


=Status LEDs on the circuit board =
==Status LEDs on the circuit board ==
[[File:TCIS Board Indications 1.png|thumb|300px|left]]
[[File:TCIS Board Indications 1.png|thumb|300px|left]]
<br style="clear:both;" />
<br style="clear:both;" />
Line 39: Line 39:
*'''Flashing 3 green''': Station connected and registered in the AlphaCom server.
*'''Flashing 3 green''': Station connected and registered in the AlphaCom server.


=Ethernet Activity & Speed LEDs on PCB=
==Ethernet Activity & Speed LEDs ==
[[File:TCIS Board Indications 2.png|thumb|300px|left]]
[[File:TCIS Board Indications 2.png|thumb|300px|left]]
<br style="clear:both;" />
<br style="clear:both;" />

Revision as of 13:33, 10 December 2019

APS.png

LEDs on Front Panel

Status LEDs

  • Bell icon lights yellow when a call is placed and ringing
  • Talk icon lights green when a call is active and in conversation
  • Door icon lights red when the door is unlocked or relay is active
TCIS Indications 1.PNG



Talk Icon: Flashing at 1 second intervals:
Station has no connection to the AlphaCom server/exchange.

Possible reasons:

  • No connection to Ethernet
  • Wrong AlphaCom XE IP address configured
  • Invalid IP address
  • No gateway or wrong gateway to the AlphaCom server/exchange
TCIS Indications 2.PNG



Talk Icon: Flashing at 5 second intervals:
Station connected but NOT registered in the AlphaCom server/exchange.

Reason:

  • Station has not been programmed in AlphaPro
TCIS Indications 3.PNG


Status LEDs on the circuit board

TCIS Board Indications 1.png


  • Flashing 2 red + 1 green: Station has no connection to the AlphaCom server.
  • Flashing 1 red + 2 green: Station connected but NOT registered in the AlphaCom server.
  • Flashing 3 green: Station connected and registered in the AlphaCom server.

Ethernet Activity & Speed LEDs

TCIS Board Indications 2.png


Green LED

  • Steady light: Ethernet connection OK
  • Flashing: Ethernet data traffic
  • No light: No Ethernet connection

Yellow LED

  • Steady light: 100 Mbit Ethernet connection
  • No light: 10 Mbit Ethernet connection