Difference between revisions of "Recorder 2.0 unable to find SQL Database"
From Zenitel Wiki
ZenitelAus (talk | contribs) |
ZenitelAus (talk | contribs) (Tag: Visual edit) |
||
Line 46: | Line 46: | ||
Close the Services window and re-complete Initial Setup. You will now be able to locate the SQL Database. | Close the Services window and re-complete Initial Setup. You will now be able to locate the SQL Database. | ||
<br /> | <br /> | ||
+ | [[Category:Recorder Troubleshooting]] |
Revision as of 05:01, 20 July 2020
When performing Recorder Initial Setup, you are unable to find the SQL database, and an error Dialog box appears;
On a fresh install of Microsoft SQL Server, the SQL Server Browser service may not be enabled.
To fix;
- Press Win + R
- Type Services.msc into the Run box
- Locate SQL Server Browser and double-click
- Set Startup Type to Automatic and Start the Service.
Close the Services window and re-complete Initial Setup. You will now be able to locate the SQL Database.