By default the physical numbers 5 and 6 on the first [[ASLT|ASLT line board]] in the [[AlphaCom XE7]] are enabled for Audio Program distribution. The potmeters P5 and P6 are used to adjust the input level. | By default the physical numbers 5 and 6 on the first [[ASLT|ASLT line board]] in the [[AlphaCom XE7]] are enabled for Audio Program distribution. The potmeters P5 and P6 are used to adjust the input level. | ||
− | { | + | {Note|An ASLT card must be present in the 1st card position} |
== Intercom stations == | == Intercom stations == |
Revision as of 11:34, 27 August 2020
Physical numbers 5 and 6 in the AlphaCom XE7 can be used either as:
- Audio Program input, or
- For regular intercom stations
Audio Program input
By default the physical numbers 5 and 6 on the first ASLT line board in the AlphaCom XE7 are enabled for Audio Program distribution. The potmeters P5 and P6 are used to adjust the input level.
{Note|An ASLT card must be present in the 1st card position}
Intercom stations
By default phys no 5 and 6 are used for Audio Program input. However, it is possible to use these physical numbers for intercom stations instead. To enable physical number 5 and/or 6 to be used for regular intercom stations:
- Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
- In AlphaPro, select Exchange & System -> Boards
- Change the port setting from ‘Audio program feed’ to ‘Default’
- Reset the exchange