Actions

Difference between revisions of "Physical number 5 and 6 (AlphaCom E7)"

From Zenitel Wiki

Line 7: Line 7:
 
By default the physical numbers 5 and 6 on the first [[ASLT|ASLT line board]] in the [[AlphaCom XE7]] are enabled for Audio Program distribution. The potmeters P5 and P6 are used to adjust the input level.
 
By default the physical numbers 5 and 6 on the first [[ASLT|ASLT line board]] in the [[AlphaCom XE7]] are enabled for Audio Program distribution. The potmeters P5 and P6 are used to adjust the input level.
  
{note|An ASLT card must be present in the 1st card position}
+
{Note|An ASLT card must be present in the 1st card position}
  
 
== Intercom stations ==
 
== Intercom stations ==

Revision as of 11:34, 27 August 2020

AlphaCom icon 300px.png

Physical numbers 5 and 6 in the AlphaCom XE7 can be used either as:

  • Audio Program input, or
  • For regular intercom stations

Audio Program input

By default the physical numbers 5 and 6 on the first ASLT line board in the AlphaCom XE7 are enabled for Audio Program distribution. The potmeters P5 and P6 are used to adjust the input level.

{Note|An ASLT card must be present in the 1st card position}

Intercom stations

By default phys no 5 and 6 are used for Audio Program input. However, it is possible to use these physical numbers for intercom stations instead. To enable physical number 5 and/or 6 to be used for regular intercom stations:

  • Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
AlphaCom XE7 backplane


  • In AlphaPro, select Exchange & System -> Boards
  • Change the port setting from ‘Audio program feed’ to ‘Default’
  • Reset the exchange
Set "Port Use" for physical number 5 and 6 to "Default"