Latest revision as of 08:18, 20 November 2020
Status LED
Bicolor SMD LED on board component side.
- Blinking 2 red + 1 green:: Station has no connection to the ICX-AlphaCom Server.
- Blinking 1 red + 2 green:: Station connected but NOT registered in the ICX-AlphaCom Server.
- Blinking 3 green:: Station connected and registered in the ICX-AlphaCom Server.
LAN LEDs
Left LED:
- Steady light: Ethernet connection OK
- Blinking: Ethernet traffic
- No light: No Ethernet connection
Right LED:
- Light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection