Actions

Difference between revisions of "INCA Video Doorstation LED Indicators"

From Zenitel Wiki

Line 7: Line 7:
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 
'''Blinking at 1 second intervals:'''<br>
 
'''Blinking at 1 second intervals:'''<br>
Station has no connection to the AlphaCom XE Audio Server.
+
Station has no connection to the ICX-AlphaCom Server.
  
 
Possible reasons:
 
Possible reasons:
Line 13: Line 13:
 
* Wrong AlphaCom IP address configured  
 
* Wrong AlphaCom IP address configured  
 
* Invalid IP address  
 
* Invalid IP address  
* No gateway or wrong gateway to the AlphaCom XE Audio Server
+
* No gateway or wrong gateway to the ICX-AlphaCom Server
  
 
'''Blinking at 5 second intervals:'''<br>
 
'''Blinking at 5 second intervals:'''<br>
Station connected but NOT registered in the AlphaCom XE Audio Server.  
+
Station connected but NOT registered in the ICX-AlphaCom Server.  
  
 
Possible reasons:  
 
Possible reasons:  
 
* Station has not been programmed in AlphaPro
 
* Station has not been programmed in AlphaPro
* Missing IP Station license in AlphaCom XE Audio Server
+
* Missing IP Station license in ICX-AlphaCom Server
  
 
'''No blinking:'''<br>
 
'''No blinking:'''<br>
  
 
Possible reasons:  
 
Possible reasons:  
* Station connected and registered to the AlphaCom XE Audio Server
+
* Station connected and registered to the ICX-AlphaCom Server
 
* Station not powered up (if no other LEDs are active)
 
* Station not powered up (if no other LEDs are active)
  
 
[[Category:Station Indication LEDs]]
 
[[Category:Station Indication LEDs]]

Revision as of 08:22, 20 November 2020

Station LED

The Station LED is integrated into the call button on the IP Video Doorstation.

IP Video Doorstation LED


Blinking at 1 second intervals:
Station has no connection to the ICX-AlphaCom Server.

Possible reasons:

  • No connection to Ethernet
  • Wrong AlphaCom IP address configured
  • Invalid IP address
  • No gateway or wrong gateway to the ICX-AlphaCom Server

Blinking at 5 second intervals:
Station connected but NOT registered in the ICX-AlphaCom Server.

Possible reasons:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in ICX-AlphaCom Server

No blinking:

Possible reasons:

  • Station connected and registered to the ICX-AlphaCom Server
  • Station not powered up (if no other LEDs are active)