Difference between revisions of "TMIS Indication LEDs"
From Zenitel Wiki
Line 8: | Line 8: | ||
'''Call button LED: Flashing at 1 second intervals''' | '''Call button LED: Flashing at 1 second intervals''' | ||
− | Station has no connection to the AlphaCom server | + | Station has no connection to the ICX-AlphaCom server. |
Possible reasons: | Possible reasons: | ||
Line 14: | Line 14: | ||
* Wrong AlphaCom XE IP address configured | * Wrong AlphaCom XE IP address configured | ||
* Invalid IP address | * Invalid IP address | ||
− | * No gateway or wrong gateway to the AlphaCom server | + | * No gateway or wrong gateway to the ICX-AlphaCom server |
[[File:TMIS-1 LED icon2.PNG|thumb|100px|left]] | [[File:TMIS-1 LED icon2.PNG|thumb|100px|left]] | ||
Line 21: | Line 21: | ||
'''Call button LED: Flashing at 5 second intervals''' | '''Call button LED: Flashing at 5 second intervals''' | ||
− | Station connected but NOT registered in the AlphaCom server | + | Station connected but NOT registered in the ICX-AlphaCom server. |
Reason: | Reason: | ||
Line 33: | Line 33: | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
'''Flashing 2 red + 1 green''' | '''Flashing 2 red + 1 green''' | ||
− | * Station has no connection to the AlphaCom server. | + | * Station has no connection to the ICX-AlphaCom server. |
'''Flashing 1 red + 2 green''' | '''Flashing 1 red + 2 green''' | ||
− | * Station connected but NOT registered in the AlphaCom server. | + | * Station connected but NOT registered in the ICX-AlphaCom server. |
'''Flashing 3 green''' | '''Flashing 3 green''' | ||
− | * Station connected and registered in the AlphaCom server. | + | * Station connected and registered in the ICX-AlphaCom server. |
=Ethernet Activity & Speed LEDs on PCB= | =Ethernet Activity & Speed LEDs on PCB= |
Revision as of 08:26, 20 November 2020
LEDs on Front Plate
Status LEDs
- - Talk icon LED lights amber when a call is active and in conversation
- - Door icon LED lights green when the door is unlocked or relay is active
Call button LED: Flashing at 1 second intervals
Station has no connection to the ICX-AlphaCom server.
Possible reasons:
- No connection to Ethernet
- Wrong AlphaCom XE IP address configured
- Invalid IP address
- No gateway or wrong gateway to the ICX-AlphaCom server
Call button LED: Flashing at 5 second intervals
Station connected but NOT registered in the ICX-AlphaCom server.
Reason:
- Station has not been programmed in AlphaPro
Status LEDs on PCB
Flashing 2 red + 1 green
- Station has no connection to the ICX-AlphaCom server.
Flashing 1 red + 2 green
- Station connected but NOT registered in the ICX-AlphaCom server.
Flashing 3 green
- Station connected and registered in the ICX-AlphaCom server.
Ethernet Activity & Speed LEDs on PCB
Green LED
- Steady light: Ethernet connection OK
- Flashing: Ethernet data traffic
- No light: No Ethernet connection
Yellow LED
- Steady light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection