Actions

INCA Substation LED Indicators: Difference between revisions

From Zenitel Wiki

 
(6 intermediate revisions by the same user not shown)
Line 1: Line 1:
==8022 - IP Substation==
===Station LED===
{|
|[[File:IP Substation Indication 1.PNG|thumb|200px|IP Substation LED]]
|[[File:IP Substation Indication 2.PNG|thumb|200px|IP Substation (3gang) LED]]
|}


===Indications===
====Station LED (on board and front plate)====
[[File:IP Substation Indication 1.PNG|left|thumb|200px|Station LED]]
<br style="clear:both;" />
[[File:IP Substation Indication 2.PNG|left|thumb|200px|Station LED]]
<br style="clear:both;" />
<br style="clear:both;" />
<u>'''Blinking at 1 second intervals:'''</u>
'''Blinking at 1 second intervals:'''<br>
*Station has no connection to the AlphaCom XE Audio Server.
Station cannot register to the server/controller


Possible reasons:
Possible reasons:
:*No connection to Ethernet
* Invalid network settings (IP address and network mask) in the device
:*Wrong AlphaCom IP address configured
* Wrong or missing account settings (Server IP, directory number, password..)
:*Invalid IP address
* Failing to register due to missing license in the server
:*No gateway or wrong gateway to the AlphaCom XE Audio Server
* The server is offline
* Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)
If the server is on a different subnet, check that
* A valid Default gateway is defined


<u>'''Blinking at 5 second intervals:'''</u>
'''No blinking:'''
*Station connected but NOT registered in the AlphaCom XE Audio Server.


Reason:  
Possible reasons:  
:*Station has not been programmed in AlphaPro
* Station connected and registered to the server/controller
:*Missing IP Station license in AlphaCom XE Audio Server
* Station not powered up (if no other LEDs are active)


<u>'''No blinking:'''</u>
'''Blinking at 5 second intervals:'''<br/>
{{Note| This LED behaviour only applies in ICX-AlphaCom mode}}
Station connected but NOT registered in the ICX-AlphaCom


Possible reasons:  
Possible reasons:  
:*Station connected and registered to the AlphaCom XE Audio Server
* Station has not been programmed in AlphaPro
:*Station not powered up (if no other LEDs are active)
* Missing IP Station license in ICX-AlphaCom
 
====Status LED====
Bicolor SMD LED on board component side.
[[File:IP Substation Indication 3.PNG|left|thumb|200px|Status LED]]
<br style="clear:both;" />
<u>'''Blinking 2 red + 1 green:'''</u>
:*Station has no connection to the AlphaCom XE Audio Server.
<u>'''Blinking 1 red + 2 green:'''</u>
:*Station connected but NOT registered in the AlphaCom XE Audio Server.
<u>'''Blinking 3 green:'''</u>
:*Station connected and registered in the AlphaCom XE Audio Server.
 
====LAN LEDs====
<u>'''Left LED:'''</u>
[[File:IP Substation Indication 4.PNG|left|thumb|200px|Left LED]]
<br style="clear:both;" />
*Steady light:  Ethernet connection OK
*Blinking:    Ethernet traffic
*No light:    No Ethernet connection


<u>'''Right LED:'''</u>
[[Category:Station Indication LEDs]]
[[File:IP Substation Indication 5.PNG|left|thumb|200px|Right LED]]
<br style="clear:both;" />
*Light:    100 Mbit Ethernet connection
*No light:  10 Mbit Ethernet connection

Latest revision as of 11:44, 20 November 2020

Station LED

IP Substation LED
IP Substation (3gang) LED


Blinking at 1 second intervals:
Station cannot register to the server/controller

Possible reasons:

  • Invalid network settings (IP address and network mask) in the device
  • Wrong or missing account settings (Server IP, directory number, password..)
  • Failing to register due to missing license in the server
  • The server is offline
  • Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)

If the server is on a different subnet, check that

  • A valid Default gateway is defined

No blinking:

Possible reasons:

  • Station connected and registered to the server/controller
  • Station not powered up (if no other LEDs are active)

Blinking at 5 second intervals:

Note icon This LED behaviour only applies in ICX-AlphaCom mode


Station connected but NOT registered in the ICX-AlphaCom

Possible reasons:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in ICX-AlphaCom
MediaWiki spam blocked by CleanTalk.