INCA Substation LED Indicators: Difference between revisions
From Zenitel Wiki
| (6 intermediate revisions by the same user not shown) | |||
| Line 1: | Line 1: | ||
== | ===Station LED=== | ||
{| | |||
|[[File:IP Substation Indication 1.PNG|thumb|200px|IP Substation LED]] | |||
|[[File:IP Substation Indication 2.PNG|thumb|200px|IP Substation (3gang) LED]] | |||
|} | |||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
'''Blinking at 1 second intervals:'''<br> | |||
Station cannot register to the server/controller | |||
Possible reasons: | Possible reasons: | ||
* Invalid network settings (IP address and network mask) in the device | |||
* Wrong or missing account settings (Server IP, directory number, password..) | |||
* Failing to register due to missing license in the server | |||
* The server is offline | |||
* Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP) | |||
If the server is on a different subnet, check that | |||
* A valid Default gateway is defined | |||
'''No blinking:''' | |||
Possible reasons: | |||
* Station connected and registered to the server/controller | |||
* Station not powered up (if no other LEDs are active) | |||
'''Blinking at 5 second intervals:'''<br/> | |||
{{Note| This LED behaviour only applies in ICX-AlphaCom mode}} | |||
Station connected but NOT registered in the ICX-AlphaCom | |||
Possible reasons: | Possible reasons: | ||
* Station has not been programmed in AlphaPro | |||
* Missing IP Station license in ICX-AlphaCom | |||
[[Category:Station Indication LEDs]] | |||
[[ | |||
Latest revision as of 11:44, 20 November 2020
Station LED
Blinking at 1 second intervals:
Station cannot register to the server/controller
Possible reasons:
- Invalid network settings (IP address and network mask) in the device
- Wrong or missing account settings (Server IP, directory number, password..)
- Failing to register due to missing license in the server
- The server is offline
- Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)
If the server is on a different subnet, check that
- A valid Default gateway is defined
No blinking:
Possible reasons:
- Station connected and registered to the server/controller
- Station not powered up (if no other LEDs are active)
Blinking at 5 second intervals:
Station connected but NOT registered in the ICX-AlphaCom
Possible reasons:
- Station has not been programmed in AlphaPro
- Missing IP Station license in ICX-AlphaCom