Actions

Difference between revisions of "INCA Substation LED Indicators"

From Zenitel Wiki

(Station LED)
 
Line 7: Line 7:
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 
'''Blinking at 1 second intervals:'''<br>
 
'''Blinking at 1 second intervals:'''<br>
Station has no connection to the ICX-AlphaCom Server.
+
Station cannot register to the server/controller
  
 
Possible reasons:
 
Possible reasons:
* No connection to Ethernet
+
* Invalid network settings (IP address and network mask) in the device
* Wrong AlphaCom IP address configured
+
* Wrong or missing account settings (Server IP, directory number, password..)
* Invalid IP address
+
* Failing to register due to missing license in the server
* No gateway or wrong gateway to the ICX-AlphaCom Server
+
* The server is offline
 +
* Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)
 +
If the server is on a different subnet, check that
 +
* A valid Default gateway is defined
  
'''Blinking at 5 second intervals:'''<br>
+
'''No blinking:'''
Station connected but NOT registered in the ICX-AlphaCom Server.
 
  
 
Possible reasons:  
 
Possible reasons:  
* Station has not been programmed in AlphaPro
+
* Station connected and registered to the server/controller
* Missing IP Station license in ICX-AlphaCom Server
+
* Station not powered up (if no other LEDs are active)
  
'''No blinking:'''<br>
+
'''Blinking at 5 second intervals:'''<br/>
 +
{{Note| This LED behaviour only applies in ICX-AlphaCom mode}}
 +
Station connected but NOT registered in the ICX-AlphaCom
  
 
Possible reasons:  
 
Possible reasons:  
* Station connected and registered to the ICX-AlphaCom Server
+
* Station has not been programmed in AlphaPro
* Station not powered up (if no other LEDs are active)
+
* Missing IP Station license in ICX-AlphaCom
  
 
[[Category:Station Indication LEDs]]
 
[[Category:Station Indication LEDs]]

Latest revision as of 11:44, 20 November 2020

Station LED

IP Substation LED
IP Substation (3gang) LED


Blinking at 1 second intervals:
Station cannot register to the server/controller

Possible reasons:

  • Invalid network settings (IP address and network mask) in the device
  • Wrong or missing account settings (Server IP, directory number, password..)
  • Failing to register due to missing license in the server
  • The server is offline
  • Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)

If the server is on a different subnet, check that

  • A valid Default gateway is defined

No blinking:

Possible reasons:

  • Station connected and registered to the server/controller
  • Station not powered up (if no other LEDs are active)

Blinking at 5 second intervals:

Note icon This LED behaviour only applies in ICX-AlphaCom mode


Station connected but NOT registered in the ICX-AlphaCom

Possible reasons:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in ICX-AlphaCom