SYNC FLASH: Difference between revisions
From Zenitel Wiki
(New page: {| border="1" |- !style="background:#ffdead;" width="90pt" colspan="2"|SYNC_FLASH !style="background:#ffdead;" width="100pt"|0xA5 !style="background:#ffdead;" width="30pt"|165 !style="bac...) |
No edit summary |
||
| (9 intermediate revisions by 4 users not shown) | |||
| Line 1: | Line 1: | ||
{{AI}} | |||
{| border="1" | {| border="1" | ||
|- | |- | ||
| Line 4: | Line 6: | ||
!style="background:#ffdead;" width="100pt"|0xA5 | !style="background:#ffdead;" width="100pt"|0xA5 | ||
!style="background:#ffdead;" width="30pt"|165 | !style="background:#ffdead;" width="30pt"|165 | ||
!style="background:#ffdead;" |AMC 10. | !style="background:#ffdead;" |AMC 10.60 | ||
|- | |- | ||
|colspan="5"|'''$SYNC_FLASH''' | |colspan="5"|'''$SYNC_FLASH''' | ||
| Line 12: | Line 14: | ||
|} | |} | ||
[[ | [[Category: ACDP messages|Category: ACDP messages]] <br /> | ||
[[ | [[AlphaNet_Data_Protocol#Station_Keyboard_.26_Display_emulation|Back to AlphaNet message list]] | ||
Restructuring when flash is synchronized. <br | Restructuring when flash is synchronized. <br /> | ||
Flash is always synchronized after AlphaPro update and before software reset if any pending changes. (No sync if sudden power or APC reset). | Flash is always synchronized after AlphaPro update (SendChg/SendAll) and before software reset if any pending changes. (No sync if sudden power or APC reset). | ||
Nvram option for different syncronization level: | Nvram option for different syncronization level: | ||
{{code|ex_profile.glob_const.flash_sync_level}} | |||
* 0 = (Default) Slow (4 hours) auto sync after DAK programming from station, $SNV, $GRM, $VOL and $SSC (Set Station class of service). | |||
* 1 = 8 second delay before auto sync after DAK, $SNV, $GRM, $VOL and $SSC | |||
Latest revision as of 08:54, 28 June 2022
| SYNC_FLASH | 0xA5 | 165 | AMC 10.60 | |
|---|---|---|---|---|
| $SYNC_FLASH | ||||
| Force synchronization of configuration database to flash | ||||
Restructuring when flash is synchronized.
Flash is always synchronized after AlphaPro update (SendChg/SendAll) and before software reset if any pending changes. (No sync if sudden power or APC reset).
Nvram option for different syncronization level:
ex_profile.glob_const.flash_sync_level
|
- 0 = (Default) Slow (4 hours) auto sync after DAK programming from station, $SNV, $GRM, $VOL and $SSC (Set Station class of service).
- 1 = 8 second delay before auto sync after DAK, $SNV, $GRM, $VOL and $SSC