Actions

Difference between revisions of "SYNC FLASH"

From Zenitel Wiki

(New page: {| border="1" |- !style="background:#ffdead;" width="90pt" colspan="2"|SYNC_FLASH !style="background:#ffdead;" width="100pt"|0xA5 !style="background:#ffdead;" width="30pt"|165 !style="bac...)
 
 
(9 intermediate revisions by 4 users not shown)
Line 1: Line 1:
 +
{{AI}}
 +
 
{| border="1"
 
{| border="1"
 
|-
 
|-
Line 4: Line 6:
 
!style="background:#ffdead;" width="100pt"|0xA5
 
!style="background:#ffdead;" width="100pt"|0xA5
 
!style="background:#ffdead;" width="30pt"|165
 
!style="background:#ffdead;" width="30pt"|165
!style="background:#ffdead;" |AMC 10.58
+
!style="background:#ffdead;" |AMC 10.60
 
|-
 
|-
 
|colspan="5"|'''$SYNC_FLASH'''  
 
|colspan="5"|'''$SYNC_FLASH'''  
Line 12: Line 14:
 
|}
 
|}
  
[[aw:Category: ACDP messages|Category: ACDP messages]] <br\>
+
[[Category: ACDP messages|Category: ACDP messages]] <br />
[[aw:AlphaNet_Data_Protocol#Station_Keyboard_.26_Display_emulation|Back to AlphaNet message list]]
+
[[AlphaNet_Data_Protocol#Station_Keyboard_.26_Display_emulation|Back to AlphaNet message list]]
  
  
  
Restructuring when flash is synchronized. <br\>
+
Restructuring when flash is synchronized. <br />
Flash is always synchronized after AlphaPro update and before software reset if any pending changes. (No sync if sudden power or APC reset).
+
Flash is always synchronized after AlphaPro update (SendChg/SendAll) and before software reset if any pending changes. (No sync if sudden power or APC reset).
  
  
 
Nvram option for different syncronization level:
 
Nvram option for different syncronization level:
  
const.flash_sync_level <br\>
+
{{code|ex_profile.glob_const.flash_sync_level}}
0 = (Default) Slow (4 hours) auto sync after DAK programming from station, $SNV, $GRM, $VOL and $SSC (Set Station class of service).  
+
* 0 = (Default) Slow (4 hours) auto sync after DAK programming from station, $SNV, $GRM, $VOL and $SSC (Set Station class of service).  
1 = 4 second delay before auto sync after DAK, $SSC, $SNV, $GRM and $VOL,
+
* 1 = 8 second delay before auto sync after DAK, $SNV, $GRM, $VOL and $SSC

Latest revision as of 08:54, 28 June 2022

AI.png
SYNC_FLASH 0xA5 165 AMC 10.60
$SYNC_FLASH
Force synchronization of configuration database to flash


Back to AlphaNet message list


Restructuring when flash is synchronized.
Flash is always synchronized after AlphaPro update (SendChg/SendAll) and before software reset if any pending changes. (No sync if sudden power or APC reset).


Nvram option for different syncronization level:

ex_profile.glob_const.flash_sync_level


  • 0 = (Default) Slow (4 hours) auto sync after DAK programming from station, $SNV, $GRM, $VOL and $SSC (Set Station class of service).
  • 1 = 8 second delay before auto sync after DAK, $SNV, $GRM, $VOL and $SSC