Latest revision as of 11:57, 30 June 2022
SET_MAIL_TIMEOUT | 0x0082 | 130 | AMC 08.10 | |
---|---|---|---|---|
$SMT L101 W0000 Q60 $SMT L%1.DIR() W%2.TAG() Q60 |
set timeout 60 - 69 seconds for station 101 example use in RECEIVED_MAIL event | |||
Set the timer of a mail queue entry. When timeout, the event MAIL_TIMEOUT is generated. 10 seconds later the mail queue entry will be deleted automatically. (All new mails are initialized by the AMC to max timer.) | ||||
1 | NET_OBJ_REF {ECL_STATION} | Station. | ||
2 | UINT2 | Mail tag (unique id) for current queue entry. | ||
3 | UINT4 | Timeout value in seconds. - The timer is ticked every 10 seconds. This means that the minimum timer value is 10 seconds, and longer times should be specified with last digit 0.<BR\>- The longest possible time is 655350 seconds, which is 7.5 days - The system guarantees a minimum timeout as specified, worst case 10 seconds later. Ex: setting 60 seconds generates timeout 60 - 69 seconds later. | ||
Response: | COMMAND_RESPONSE |