Actions

Difference between revisions of "Starting Up Turbine TFIX-V2 Station"

From Zenitel Wiki

(How to find the IP Address of the station)
(How to find the IP Address of the station)
 
(One intermediate revision by the same user not shown)
Line 19: Line 19:
  
 
During commissioning, the station must be set to operate in the required mode. There are three modes of operation:
 
During commissioning, the station must be set to operate in the required mode. There are three modes of operation:
* '''ICX-AlphaCom mode''' - the station will register to an AlphaCom server
+
* '''ICX-AlphaCom mode''' - the station will register to an ICX-AlphaCom server
* '''SIP mode''' - the station will regiter to a SIP server
+
* '''SIP mode''' - the station will register to a SIP server
 
* '''IC-Edge mode''' - the station will register to a IC-Edge server
 
* '''IC-Edge mode''' - the station will register to a IC-Edge server
  
 
[[Category: Turbine - Restore Factory Defaults and Software Upgrade]]
 
[[Category: Turbine - Restore Factory Defaults and Software Upgrade]]

Latest revision as of 10:04, 10 August 2022

AEIS.png
Connecting the PC and the TFIX-V2 station to a network switch

The Turbine EX Station (TFIX-V2) features an embedded web interface, which allows users to log in via a standard web browser.

To access the station from your PC, the PC and the TFIX-V2 station have to be connected to a network switch:

  1. Connect the PC to the switch
  2. Connect the Flowire FCDC-3 to the switch
  3. Connect the TFIX-V2 station to the FCDC-3 using two wires
  4. Connect 24-48VDC (48VDC recommended) to the Flowire FCDC-3
  5. The station will now start up
  6. After startup, an IP address is automatically obtained in one of two ways:
    1. An IP address is obtained from a DHCP server if there is one.
    2. If there is no DHCP server, a random IP address in the range 169.254.x.x will be assigned.


How to find the IP Address of the station

If the station is not registered to a server, it will speak its own IP address when you press the Call button, a Digit key or a DAK key on the station

At startup the station is by default set to operate in IC-Edge mode.

During commissioning, the station must be set to operate in the required mode. There are three modes of operation:

  • ICX-AlphaCom mode - the station will register to an ICX-AlphaCom server
  • SIP mode - the station will register to a SIP server
  • IC-Edge mode - the station will register to a IC-Edge server