Actions

Difference between revisions of "Modify ASVP alarm message repetitions"

From Zenitel Wiki

(Example)
Line 4: Line 4:
  
 
===Procedure===
 
===Procedure===
* From the nvram editor in the TST-console, go to:
+
* From the [[TST_console#NVRAM_editor|nvram editor]] in the TST-console, go to:
  
 
  .ex_mi.announce_tab[n].repeat       
 
  .ex_mi.announce_tab[n].repeat       

Revision as of 06:44, 30 July 2012

By default the ASVP alarm messages are repeated endlessly, but for some applications it is required that the message is played once or a few times and then stop. For each alarm message there is a parameter that controls the number of repetitions. As this parameter is not available from AlphaPro, it has to be changed directly in the AMC memory, using the nvram editor in the TST console.

NOTE: Before continuing it is highly recommended to do a backup of AMC memory to Flash. Dial 7820+M from a SuperUser station.

Procedure

.ex_mi.announce_tab[n].repeat       

where n = message number.

Set number of repetitions of the alarm message (1 to 255, 255 is endless)


Example

This example shows how to change the parameter for alarm message 1 (Directory number 8191) to play once, then stop:

Type: Explanation
nvram <Enter><Enter> Start the nvram editor from the TST console
2 <Enter> Enter line 2: .ex_mi…
2 <Enter> Enter line 2: .ex_mi_announce_tab[81]
1 <Enter> Select alarm message number 1 (*)
3 <Enter> Enter line 3: ….tab[1].repeat = 255
1 <Enter> Set number of repetitions of alarm message, here 1
Q <Enter> Exit NVRAM table

(*) Use message number 2 - 9 for the messages 8192 - 8199.