Actions

Difference between revisions of "MRBD - Relay Board"

From Zenitel Wiki

(Related Articles)
 
(43 intermediate revisions by 3 users not shown)
Line 1: Line 1:
The '''MRBD''' relay board has six relays, which are controlled by [[RCO]]'s from the exchnage or from a [[RIO]] unit. The MRBD must be powered by +24 VDC. The [[AlphaCom E7]] and E20 comes with a 24VDC outlet for such purpose, but in the AlphaCom E26 a [[PDB|Power Distribution Board PDB]] is required.
+
[[Image:1009970200.PNG|thumb|250px|The MRBD board - 1009970200]]
  
The RCOs can be activated by a high or low level. This is determined by jumper setting on the board. High level is used in AlphaCom installations, while low level is used in TouchLine Compact installations.
+
==Highlights==
 +
* Equipped with 6 dual changeover relays and relay drivers
 +
* Powered by +24 VDC
 +
* Connector for 6 RCOs + 2 GND reference signals
 +
* Connects to the AlphaCom Subscriber Connection Board through a 1:1 cable
 +
* Fastens onto mounting rail in AlphaCom exchange
 +
* Relay switching capacity:  125VDC/AC, 1.25A.
 +
** 1,25A is maximum carrying current, maximum switching current at 125VAC is 0,5A. (approx. 60W).
  
In the AlphaCom exchange it is recommended that all the RCOs be connected to the same ASLT board(s) in order to simplify cabling.
+
==Additional Documentation==
 +
* [http://www.zenitel.com/product/mrbd Additional Documentation on Zenitel.com]
  
The Multi-Relay board is supplied in an installation box that can be fastened onto the mounting rail on the connection field of the AlphaCom exchange, or mounted on the wall in any suitable position.
+
==Connectors and Switches==
 +
[[image:MRBD-1.PNG|thumb|left|600px|Connectors and switches on MRBD board]]
 +
<br style="clear:both;" />
  
== Features ==
+
The jumpers S1-S6 determine if the RCO should be activated by a high or low level. High level is used in AlphaCom system, while low level was used in the previous TouchLine generation of intercom system.
* Equipped with 6 dual change over relays and relay drivers
+
 
* Runs on +24 V supplied from the Power Distribution Board PDB.
+
==Connections==
* Accepts RCOs with high- or low-level switch setting on the board
+
===AlphaCom XE7===
* Connector for 6 RCOs + 2 GND reference signals
+
In the XE7 the cable is connected to the 8-pin pinheader labeled '''RCO 1-6''' or '''RCO 7-12'''.
* Connects to the AlphaCom Subscriber Connection Board through a 1:1 cable
+
 
* Fastens onto mounting rail in AlphaCom exchange
+
* An [[ASLT|ASLT board]] in board position 1 is required to operate RCO 1 - 6.
 +
* An [[ASLT|ASLT board]] in board position 2 is required to operate RCO 7 - 12.
 +
[[Image:DoorOpening E7.jpg|thumb|300px|left|Connection of MRBD in an AlphaCom XE7]]
 +
<br style="clear:both;" />
  
==Technical Specifications==
+
===AlphaCom XE20/26===
{| border="1"
 
|-
 
!style="background:#ffdead;" width="100pt"|Text
 
!style="background:#ffdead;" width="100pt"|Value
 
|-
 
|Order Number||align=center|1009970200
 
|-
 
|Input Voltage: <br>
 
Maximum Current:<br>
 
Current through relay contact:<br>
 
|| +24 VDC
 
60 mA (all relays active simultaneously)<br>
 
1A
 
|-
 
|Relays||align=centrer|6 relays each with 2 changeover contacts
 
|-
 
|RCOs<br\><br\><br\>||align=center|Active high or low<br\>(switch setting on the board)<br\>high = AlphaCom<br\>low = TouchLine Compact
 
|-
 
|Recommended room temperature<br\>(non-condensing)||align=center|0'C to + 35'C<br\>+32'F to + 95' F
 
|-
 
|Humidity Range:||align=center|10% - 90% RH
 
|-
 
|Dimensions:||align=center|100 mm x 100 mm<br\>3.9" x3.9"
 
|-
 
|Connector Types:||Spring terminals, AMP MTA 100 connector
 
|}
 
  
== Connectors and Switches ==
+
[[File:RCO XE20.PNG|thumb|500px|left|Connection of MRBD in an AlphaCom XE20]]
[[image:MRBD Connectors and switches on MRBD board.jpg|thumb|left|600px|Connectors and switches on MRBD board]]
 
 
<br style="clear:both;" />
 
<br style="clear:both;" />
[[Category:AlphaCom E System]]
+
 
 +
 
 +
In an AlphaCom XE26 the 24VDC power is provided by the [[PDB|Power Distribution Board PDB]].
 +
 
 +
==Related Articles==
 +
*[[Adding additional relay(s) to a Zenitel IP Device]]
 +
 
 +
[[Category:Additional equipment]]

Latest revision as of 15:12, 23 June 2023

The MRBD board - 1009970200

Highlights

  • Equipped with 6 dual changeover relays and relay drivers
  • Powered by +24 VDC
  • Connector for 6 RCOs + 2 GND reference signals
  • Connects to the AlphaCom Subscriber Connection Board through a 1:1 cable
  • Fastens onto mounting rail in AlphaCom exchange
  • Relay switching capacity: 125VDC/AC, 1.25A.
    • 1,25A is maximum carrying current, maximum switching current at 125VAC is 0,5A. (approx. 60W).

Additional Documentation

Connectors and Switches

Connectors and switches on MRBD board


The jumpers S1-S6 determine if the RCO should be activated by a high or low level. High level is used in AlphaCom system, while low level was used in the previous TouchLine generation of intercom system.

Connections

AlphaCom XE7

In the XE7 the cable is connected to the 8-pin pinheader labeled RCO 1-6 or RCO 7-12.

  • An ASLT board in board position 1 is required to operate RCO 1 - 6.
  • An ASLT board in board position 2 is required to operate RCO 7 - 12.
Connection of MRBD in an AlphaCom XE7


AlphaCom XE20/26

Connection of MRBD in an AlphaCom XE20



In an AlphaCom XE26 the 24VDC power is provided by the Power Distribution Board PDB.