(404) Not Found: Difference between revisions
From Zenitel Wiki
(Created page with "thumb|left|700px <br style="clear:both;" /> This error appears when using AlphaPro version 12 (or newer) on an AlphaCom with software version 11...") |
Lennert.werf (talk | contribs) No edit summary |
||
| (One intermediate revision by one other user not shown) | |||
| Line 1: | Line 1: | ||
{{AI}} | |||
[[File:AlphaProError404.png|thumb|left|700px]] | [[File:AlphaProError404.png|thumb|left|700px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
This error appears when using AlphaPro version 12 (or newer) on an AlphaCom with software version 11.5.x.x or lower. | This error appears when using AlphaPro version 12 (or newer) on an AlphaCom with software version 11.5.x.x or lower. | ||
Reason: | |||
* As from version AlphaPro 12.0, AlphaPro does GetAll using http requests (port 80). This is supported on the AlphaCom server side as from AlphaCom ver. 12 | |||
Solution: | Solution: | ||
* Upgrade AlphaCom to latest version, or | * Upgrade AlphaCom to latest version (must be 12 or higher), or | ||
* Use AlphaPro 11.7.3.2 | * Use AlphaPro 11.7.3.2 | ||
[[Category:AlphaPro Troubleshooting]] | [[Category:AlphaPro Troubleshooting]] | ||
Latest revision as of 09:52, 24 October 2023
This error appears when using AlphaPro version 12 (or newer) on an AlphaCom with software version 11.5.x.x or lower.
Reason:
- As from version AlphaPro 12.0, AlphaPro does GetAll using http requests (port 80). This is supported on the AlphaCom server side as from AlphaCom ver. 12
Solution:
- Upgrade AlphaCom to latest version (must be 12 or higher), or
- Use AlphaPro 11.7.3.2