(Created page with "{{AI}} This article shows how to configure the VS-Operator to control Remote Control Outputs (RCO) by clicking on a dedicated RCO icon on t...")
 
Line 1: Line 1:
{{AI}} This article shows how to configure the [[VS-Operator]] to control [[RCO - Remote Control Output|Remote Control Outputs (RCO)]] by clicking on a dedicated RCO icon on the map. The icon will change appearance according to the state (idle or active). Correct state will be shown regardless if the RCO is triggered from the VSOP or from any other action in the system.
+
{{AI}} This article shows how to configure the logging feature in the [[VS-Operator]].
  
In the following example we will make two different scripts for RCO operation, one which will pulse the RCO for a predefined time, and one which will toggle the RCO on or off, depending on the current state.
+
Information can be logged into the onscreen log ('''Show''') and to disk ('''Log'''). The information to be logged is defined in the field '''Message text'''. It is possible to add parameters into this text field.
  
== Prerequisites ==
+
In the case of '''OnConnect''' a Message text could be:
# The VS-Operator is already installed and operational
+
* Call %DIROP %DIRB
# [[Exchange_%26_System_(AlphaPro)#RCO|A logical RCO is already defined]] in the ICX or AlphaCom using AlphaPro.
+
** %DIROP will be replaced with the directory number of the station assosiated to the V-S Operator
  
== Create a script for pulsing an RCO for 3.0 seconds ==
 
* In the VSOP Client, select '''Script sets''', and '''Add''' a script for '''RCO''', and in the '''Caption''' field assign a descriptive name to the script.
 
* Select '''State idle''', then '''Add'''. Enter the following script text ("W30" means 3.0 seconds):
 
 
{{code|App.STE("$SLRC W%RCO U1 W30");}}
 
 
[[Image:VSOP Script RCO timer.PNG|thumb|700px|left|Script for pulsing an RCO for 3.0 seconds]]
 
<br style="clear:both;" />
 
 
 
If the '''Default''' flag is enabled, the script will be executed when clicking on the RCO icon. If the '''Default''' flag is not enabled, one have to right-click the RCO icon, then select the command "Activate" to execute the script.
 
 
== Create a script for toggling an RCO on and off ==
 
* In the VSOP Client, select '''Script sets''', and '''Add''' a script for '''RCO''', and in the '''Caption''' field assign a descriptive name to the script.
 
* Select '''State idle''', then '''Add'''. Enter the following script text:
 
{{code|App.STE("$SLRC W%RCO U1");}}
 
 
[[Image:VSOP RCO ON.PNG|thumb|700px|left|Script for toggling the RCO on]]
 
<br style="clear:both;" />
 
 
 
If the '''Default''' flag is enabled, the script will be executed when clicking on the RCO icon. If the '''Default''' flag is not enabled, one have to right-click the RCO icon, then select the command "Set RCO" to execute the script.
 
 
 
* Select '''State active''', then '''Add'''. Enter the following script text:
 
{{code|App.STE("$SLRC W%RCO U0");}}
 
 
[[Image:VSOP RCO OFF.PNG|thumb|700px|left|Script for toggling the RCO off]]
 
<br style="clear:both;" />
 
 
 
Again, if the '''Default''' flag is enabled, the script will be executed when clicking on the RCO icon.
 
 
==Define the RCO device and assign script to it==
 
In the VSOP Client, '''Add''' a new '''RCO''' device:
 
 
[[Image:VSOP Add RCO.PNG|thumb|700px|left|Adding an RCO device]]
 
<br style="clear:both;" />
 
 
Select the new RCO device from the devicelist, and choose '''Selected object''' from the menu. Configure the following parameters:
 
* '''Caption''' - any descriptive text
 
* '''Script set''' - assign one of the already defined RCO scripts
 
* '''Node number''' - The AlphaCom node number (default is "1")
 
* '''RCO number''' - The logical RCO number as defined in the RCO table in AlphaPro
 
 
[[Image:VSOP RCO config.png|thumb|700px|left|Configuring the RCO device]]
 
<br style="clear:both;" />
 
 
== Place the RCO icon on a map ==
 
* In the VSOP Client, select '''Map pages'''
 
* Drag an already imported map to the middle of the screen
 
* From the device list, drag the RCO device and drop it on the map
 
  
 
[[Image:VSOP RCO to map.png|thumb|700px|left|Place the RCO on the map]]
 
[[Image:VSOP RCO to map.png|thumb|700px|left|Place the RCO on the map]]

Revision as of 15:36, 7 November 2023

AI.png

This article shows how to configure the logging feature in the VS-Operator.

Information can be logged into the onscreen log (Show) and to disk (Log). The information to be logged is defined in the field Message text. It is possible to add parameters into this text field.

In the case of OnConnect a Message text could be:

  • Call %DIROP %DIRB
    • %DIROP will be replaced with the directory number of the station assosiated to the V-S Operator


Place the RCO on the map



Now change the mode of operation to Operational, and verify that the RCO is triggered when clicking on the RCO icon, or alternatively when right-clicking the icon and selecting the command.