Actions

Difference between revisions of "Logging (VS-Operator)"

From Zenitel Wiki

Line 18: Line 18:
 
! style="background:#ffc400;" width="600" |'''Comment'''
 
! style="background:#ffc400;" width="600" |'''Comment'''
 
|-
 
|-
| align=center| On CallRequest Add || align=center| 10.00 (2006-06-01) ||align=center| 10.54 (2009-06-04) || All AMC releated software and AlphaWeb
+
| align=center| On CallRequest Add || align=center| Call received ||align=center| 10.54 (2009-06-04) || All AMC releated software and AlphaWeb
 
|-
 
|-
| align=center| On CallRequest Remove || align=center| 01.00 (2008-xx-xx) ||align=center| 01.00 (2008-xx-xx) || Linux system files, libraries, webserver etc. (Board Support Package patch)
+
| align=center| On CallRequest Remove || align=center| Call removed from queue ||align=center| Info || Linux system files, libraries, webserver etc. (Board Support Package patch)
 
|-
 
|-
| align=center| OnConnect || align=center| 01.00 (2008-xx-xx) ||align=center| 01.00 (2008-xx-xx) || Other AlphaCom Daemons - rmd, m100d
+
| align=center| OnConnect || align=center| Conversation ||align=center| Info || Other AlphaCom Daemons - rmd, m100d
 
|-
 
|-
| align=center| OnDisconnect || align=center| 01.00 (2008-xx-xx) ||align=center| 01.00 (2008-xx-xx) || Billing Software, absd, Billing Web etc
+
| align=center| OnDisconnect || align=center| Conversation ended ||align=center| Info || Billing Software, absd, Billing Web etc
 
|-
 
|-
| align=center| OnError|| align=center| 01.00 (2008-xx-xx) ||align=center| 01.00 (2008-xx-xx) || Billing Software, absd, Billing Web etc
+
| align=center| OnError|| align=center| Device error ||align=center| Alarm || Billing Software, absd, Billing Web etc
 
|-
 
|-
| align=center| On Custom params|| align=center| 01.00 (2008-xx-xx) ||align=center| 01.00 (2008-xx-xx) || Billing Software, absd, Billing Web etc
+
| align=center| On Custom params|| align=center| xxx ||align=center| <depends on the evennt> || Billing Software, absd, Billing Web etc
 
|-
 
|-
| align=center| On Custom word string || align=center| 01.00 (2008-xx-xx) ||align=center| 01.00 (2008-xx-xx) || Billing Software, absd, Billing Web etc
+
| align=center| On Custom word string || align=center| xxx ||align=center| yy || Billing Software, absd, Billing Web etc
 
|-
 
|-
 
|}
 
|}

Revision as of 16:04, 7 November 2023

AI.png

This article shows how to configure the logging feature in the VS-Operator.

In the VSOP Client, select Filter sets, and Add a filter set for Station, and in the Caption field assign a descriptive name to the filter set, e.g. "Journal".

Information can be logged into the onscreen journal (Show) and to disk (Log).

Configuring Filter Set "Journal" for logging. Here "Call Received" is logged when a call request is received



The text to send to the log is defined in the field Message text. For example:

Event Message text Information Level Comment
On CallRequest Add Call received 10.54 (2009-06-04) All AMC releated software and AlphaWeb
On CallRequest Remove Call removed from queue Info Linux system files, libraries, webserver etc. (Board Support Package patch)
OnConnect Conversation Info Other AlphaCom Daemons - rmd, m100d
OnDisconnect Conversation ended Info Billing Software, absd, Billing Web etc
OnError Device error Alarm Billing Software, absd, Billing Web etc
On Custom params xxx <depends on the evennt> Billing Software, absd, Billing Web etc
On Custom word string xxx yy Billing Software, absd, Billing Web etc



It is possible to add parameters into this text field.

In the case of OnConnect a Message text could be:

  • Call %DIROP %DIRB
    • %DIROP will be replaced with the directory number of the station assosiated to the V-S Operator
App.STE("$SLRC W%RCO U1 W30");


Configuring Filter Set for logging



Now change the mode of operation to Operational, and verify that the RCO is triggered when clicking on the RCO icon, or alternatively when right-clicking the icon and selecting the command.