Actions

Difference between revisions of "Logging (VS-Operator)"

From Zenitel Wiki

Line 46: Line 46:
  
  
[[Image:VSOP Journal 3.png|thumb|700px|left|Output to the log when using the "Message text" from examples above]]
+
[[Image:VSOP Journal 3.png|thumb|700px|left|Door Opening event in AlphaPro event handler]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  

Revision as of 16:57, 7 November 2023

AI.png

This article shows how to configure the logging feature in the VS-Operator.

In the VSOP Client, select Filter sets, and Add a filter set for Station, and in the Caption field assign a descriptive name to the filter set, e.g. "Journal".

Information can be logged into the onscreen journal (Show) and to disk (Log).

Configuring Filter Set "Journal" for logging. Here "Call Received from <number> <name>" is logged when a call request is received



The text to send to the log is defined in the field Message text.

Here are some examples that can be used

Event Text in "Message text" field Information Level Comment
On CallRequest Add Call received from %DIRA %ACAPTION Info Triggered when a Ringing Group call (or Call Request) is received
On CallRequest Remove Call from %DIRA %ACAPTION removed from queue Info Triggered when a call is removed from the call queue
OnConnect Conversation with %DIRB %BCAPTION Info Triggered when a conversation is established
OnDisconnect Conversation with %DIRB %BCAPTION ended Info Triggered when a conversation is terminated
OnError Device error at %DIRA %ACAPTION Alarm Triggered when a station or device is reported faulty
On Custom params Door Opening triggered at %DIRA %ACAPTION Warning Triggers on "custom parameter" send from ICX-AlphaCom when Door Opening is activated
On Custom word string <depends on the event> <depends on the event> Triggers on custom event


In order to log Door Opening event one have to add a "custom parameter" event in the Door Opening event in the ICX-AlphaCom. For each door openoing event one need to add the following code:


Action commands:
IF %chg(1,0)
@*D1 M7F01 L(1)%1.dir U0 W0 W0 W0 W1 W1
ENDIF



Door Opening event in AlphaPro event handler



Now change the mode of operation to Operational, and verify that the Journal displays the correct information:

Output to the log when using the "Message text" from examples above