Actions

Difference between revisions of "Upgrading old intercom system"

From Zenitel Wiki

(Bus structure)
(Bus structure)
 
(8 intermediate revisions by 3 users not shown)
Line 21: Line 21:
 
* TouchLine Compact (TLC)
 
* TouchLine Compact (TLC)
 
[[File:Upgrade old systems 3.png|thumb|left|500px]]
 
[[File:Upgrade old systems 3.png|thumb|left|500px]]
 +
<br style="clear:both;" />
 +
 
'''Wiring and Stations'''
 
'''Wiring and Stations'''
 
* Keep existing wiring (2 pairs, star wiring)
 
* Keep existing wiring (2 pairs, star wiring)
Line 38: Line 40:
 
* Insert XE7 in the midle of the star and reuse cabling
 
* Insert XE7 in the midle of the star and reuse cabling
 
* All Micom stations (15xx) must be swapped to analgoue stations (1007xxxxxx)
 
* All Micom stations (15xx) must be swapped to analgoue stations (1007xxxxxx)
 +
[[File:Upgrade old systems 6.png|thumb|left|500px]]
 +
<br style="clear:both;" />
  
 
=== Bus structure ===
 
=== Bus structure ===
* Replace entire system with Vingtor-Stentofon Pulse
+
* Replace entire system with IC-Edge
 
* Replace all stations with IP Stations (1008xxxxxx)
 
* Replace all stations with IP Stations (1008xxxxxx)
 +
[[File:Upgrade old systems 5.png|thumb|left|500px|Edge system]]
 +
<br style="clear:both;" />
  
  
[[Category:Hardware]]
+
[[Category:AlphaCom Hardware]]

Latest revision as of 15:37, 21 November 2024

STENTOFON Pamex and TouchLine

48 to 1040 lines

Exchanges (1975-1995)

  • Pamex
  • Pamex MPC
  • TouchLine
Upgrade old systems 1.png


Wiring and Stations

  • Keep existing wiring (2 pairs, star wiring)
  • Existing stations might be kept
Stations with article numbers 10006xxxxx & 1007xxxxxx


ST20 and P16/32

Exchanges (1975-1999)

16 to 32 lines
  • ST20
  • Pamex 16/32 (P16/32)
  • TouchLine Compact (TLC)
Upgrade old systems 3.png


Wiring and Stations

  • Keep existing wiring (2 pairs, star wiring)
  • Existing stations might be kept
Stations with article numbers 10006xxxxx & 1007xxxxxx


Micom

Micom (1982 - 1999)

Exchangeless system
Stations with article number 15xx


Micom was a bus-based system using 3 pairs. Replacement options depends on existing structure:

Star connected

  • Insert XE7 in the midle of the star and reuse cabling
  • All Micom stations (15xx) must be swapped to analgoue stations (1007xxxxxx)
Upgrade old systems 6.png


Bus structure

  • Replace entire system with IC-Edge
  • Replace all stations with IP Stations (1008xxxxxx)
Edge system