| Line 15: | Line 15: | ||
| 2¹ || 5V+ || 5 volt output | | 2¹ || 5V+ || 5 volt output | ||
|- | |- | ||
| 3¹ || Ext speaker (8ohm) || Connection for external 8 ohm loudspeaker | | 3¹ || Ext speaker (8ohm) || Connection for external 8 ohm loudspeaker | ||
|- | |- | ||
| 4¹ || Ext speaker (8ohm) || Connection for external 8 ohm loudspeaker | | 4¹ || Ext speaker (8ohm) || Connection for external 8 ohm loudspeaker | ||
|- | |- | ||
| 5¹ || Int speaker (8ohm) || Connection for internal 8 ohm loudspeaker | | 5¹ || Int speaker (8ohm) || Connection for internal 8 ohm loudspeaker | ||
|- | |- | ||
| 6¹ || Int speaker (8ohm) || Connection for internal 8 ohm loudspeaker | | 6¹ || Int speaker (8ohm) || Connection for internal 8 ohm loudspeaker | ||
|- | |- | ||
| 7 || Relay CO || Relay output, Common | | 7 || Relay CO || Relay output, Common | ||
| Line 27: | Line 27: | ||
| 8 || Relay NO || Relay output, Normal Open | | 8 || Relay NO || Relay output, Normal Open | ||
|- | |- | ||
| 9 || Line in/Mic || Audio input (positive | | 9 || Line in/Mic || Audio input (positive) | ||
|- | |- | ||
| 10 || Line in/Mic || Audio input (negative | | 10 || Line in/Mic || Audio input (negative) | ||
|- | |- | ||
| 11 || GND || Ground connector | | 11 || GND || Ground connector | ||
Revision as of 14:23, 13 January 2025
| Pin | Description | Comment |
| 1¹ | GPIO | General Purpose In Out |
| 2¹ | 5V+ | 5 volt output |
| 3¹ | Ext speaker (8ohm) | Connection for external 8 ohm loudspeaker |
| 4¹ | Ext speaker (8ohm) | Connection for external 8 ohm loudspeaker |
| 5¹ | Int speaker (8ohm) | Connection for internal 8 ohm loudspeaker |
| 6¹ | Int speaker (8ohm) | Connection for internal 8 ohm loudspeaker |
| 7 | Relay CO | Relay output, Common |
| 8 | Relay NO | Relay output, Normal Open |
| 9 | Line in/Mic | Audio input (positive) |
| 10 | Line in/Mic | Audio input (negative) |
| 11 | GND | Ground connector |
|
¹) Connectable conductors: 0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm². |
|