Difference between revisions of "SET SYSTEM TIME"
From Zenitel Wiki
Line 1: | Line 1: | ||
{| border="1" align=left | {| border="1" align=left | ||
|- | |- | ||
− | !width="90pt" colspan="2"|SET_SYSTEM_TIME | + | !style="background:#ffdead;" width="90pt" colspan="2"|SET_SYSTEM_TIME |
− | !width="100pt"|0x0027 | + | !style="background:#ffdead;" width="100pt"|0x0027 |
− | !width="30pt"|39 | + | !style="background:#ffdead;" width="30pt"|39 |
− | !width="100pt"|AMC 05.00 | + | !style="background:#ffdead;" width="100pt"|AMC 05.00 |
|- | |- | ||
|colspan="5"|'''$SST W1999 U12 U31 U23 U59 U59''' <br\> '''$SST FFFF FF FF U03 U02 FF''' | |colspan="5"|'''$SST W1999 U12 U31 U23 U59 U59''' <br\> '''$SST FFFF FF FF U03 U02 FF''' | ||
Line 10: | Line 10: | ||
|colspan="5"|Set a device’s internal clock to the given date and time. | |colspan="5"|Set a device’s internal clock to the given date and time. | ||
|- | |- | ||
− | |1||[[CLOCK]]||colspan="3"|Date and time<br\>[[AMC]] 08.01: Use the value 0xFF in any field to keep the value already in the real-time clock. Application: External clock can via [[RCI]] synchronize [[AlphaCom]]’s HH:MM setting once per day without changing the other fields. | + | |align=center|1||[[CLOCK]]||colspan="3"|Date and time<br\>[[AMC]] 08.01: Use the value 0xFF in any field to keep the value already in the real-time clock. Application: External clock can via [[RCI]] synchronize [[AlphaCom]]’s HH:MM setting once per day without changing the other fields. |
|- | |- | ||
|colspan="2"|Response:||colspan="3"|[[SYSTEM_TIME]] | |colspan="2"|Response:||colspan="3"|[[SYSTEM_TIME]] | ||
|- | |- | ||
|} | |} |
Revision as of 08:46, 20 June 2007
SET_SYSTEM_TIME | 0x0027 | 39 | AMC 05.00 | |
---|---|---|---|---|
$SST W1999 U12 U31 U23 U59 U59 <br\> $SST FFFF FF FF U03 U02 FF | ||||
Set a device’s internal clock to the given date and time. | ||||
1 | CLOCK | Date and time<br\>AMC 08.01: Use the value 0xFF in any field to keep the value already in the real-time clock. Application: External clock can via RCI synchronize AlphaCom’s HH:MM setting once per day without changing the other fields. | ||
Response: | SYSTEM_TIME |