SCAN_RCI_ONCE 0x0020 32 AMC 05.00
$SCAN W1 U3 U5
Scan input until defined condition is met, then report to exchange.
1 UINT2 Input pin number
2 UINT1 Scan mode: <br\>0 = Stop scan <br\>1 = Report when input is off <br\>2 = Report when input is on <br\>3 = Report when input changes (both on and off)
3 UINT1 Stabilization time. Unit = 10ms.
Response: SCAN_RCI_ACK