| It may be desired to reset an IP Hotline Station to its original settings if, for instance, the password for the web server is forgotten.
| |
|
| |
| The defaults can be either be set to Static IP or Activated DHCP (when there are many new IP Substations in an installation).
| |
|
| |
| === Restore with Static IP ===
| |
| # While lifting the handset, power up the station.
| |
| # When the station LED starts blinking, replace the handset '''after exactly 2 blinks'''.
| |
| # Let the LED blink for '''exactly 2 more times''', then lift the handset again.
| |
| # Keep the handset lifted until the LED '''blinks fast 2 times''' indicating a successful reset with static IP.
| |
| # Replace the handset and the station will restart with the factory default settings.
| |
| [[File:IP Hotline Station LED 2.PNG|left|thumb|300px]]
| |
| <br style="clear:both;" />
| |
|
| |
| {| class="wikitable"
| |
| !style="background:#ffdead" colspan="2"|Factory default values
| |
| |-
| |
| | Station Mode || align=center | '''Pulse'''
| |
| |-
| |
| | Station IP address || align=center | '''169.254.1.100'''
| |
| |-
| |
| | AlphaCom IP address || align=center | '''169.254.1.5'''
| |
| |-
| |
| | Username* || align=center | '''admin'''
| |
| |-
| |
| | Password* || align=center | '''alphaadmin'''
| |
| |-
| |
| |}
| |
|
| |
| * Software 01.06 and earlier: '''ADMIN/alphacom''')
| |
|
| |
| === Restore with Activated DHCP ===
| |
| The DHCP option is available from software version 01.07.
| |
| # While lifting the handset, power up the station.
| |
| # When the station LED starts blinking, replace the handset '''after exactly 2 blinks'''.
| |
| # Let the LED blink for '''exactly 4 more times''', then lift the handset again.
| |
| # Keep the handset lifted until the LED '''blinks fast 4 times''' indicating a successful reset with activated DHCP.
| |
| # Replace the handset and the station will restart with the factory default settings.
| |
|
| |
| {| class="wikitable"
| |
| !style="background:#ffdead" colspan="2"|Factory default values
| |
| |-
| |
| | Station Mode || align=center | '''Pulse'''
| |
| |-
| |
| | Station IP address || align=center | '''determined by DHCP server'''
| |
| |-
| |
| | AlphaCom IP address || align=center | '''169.254.1.5'''
| |
| |-
| |
| | Username* || align=center | '''admin'''
| |
| |-
| |
| | Password* || align=center | '''alphaadmin'''
| |
| |-
| |
| |}
| |
|
| |
| * Software 01.06 and earlier: '''ADMIN/alphacom''')
| |
|
| |
|
| [[Category: INCA - Restore Factory Defaults and Software Upgrade]] | | [[Category: INCA - Restore Factory Defaults and Software Upgrade]] |