Difference between revisions of "Physical number 5 and 6 (AlphaCom E7)"
From Zenitel Wiki
(New page: Describe here how to change port 5 and 6 to stations.) |
|||
Line 1: | Line 1: | ||
− | + | Connector 5 and 6 on the first ASLT line board are enabled for program distribution by default. | |
+ | Additional programs can also be connected to individual ASLT ports via the interface board [[FBSAR]], 6 programs per board. | ||
+ | |||
+ | * To set physical number 5 and/or 6 to be used as program distribution inputs on line c-d when an ASLT board is placed in board pos. 1: | ||
+ | :* The jumpers P5 and P6 are set to pos 2-3. | ||
+ | :* The potmeters P5 and P6 are used to adjust the input level. | ||
+ | |||
+ | * To set physical number 5 and/or 6 to be used as normal subscriber ports: | ||
+ | :* Set jumpers 5 and 6 to pos 1-2 | ||
+ | :* In AlphaPro, select Exchange & System -> Boards | ||
+ | :* Change the port setting from ‘Audio program feed’ to ‘Default’ | ||
+ | :* Reset the exchange |
Revision as of 13:21, 4 February 2009
Connector 5 and 6 on the first ASLT line board are enabled for program distribution by default. Additional programs can also be connected to individual ASLT ports via the interface board FBSAR, 6 programs per board.
- To set physical number 5 and/or 6 to be used as program distribution inputs on line c-d when an ASLT board is placed in board pos. 1:
- The jumpers P5 and P6 are set to pos 2-3.
- The potmeters P5 and P6 are used to adjust the input level.
- To set physical number 5 and/or 6 to be used as normal subscriber ports:
- Set jumpers 5 and 6 to pos 1-2
- In AlphaPro, select Exchange & System -> Boards
- Change the port setting from ‘Audio program feed’ to ‘Default’
- Reset the exchange