Difference between revisions of "Physical number 5 and 6 (AlphaCom E7)"
From Zenitel Wiki
Line 3: | Line 3: | ||
* To set physical number 5 and/or 6 to be used as normal subscriber ports: | * To set physical number 5 and/or 6 to be used as normal subscriber ports: | ||
:* Set jumpers 5 and 6 to pos 1-2 | :* Set jumpers 5 and 6 to pos 1-2 | ||
− | :* In AlphaPro, select Exchange & System -> Boards | + | :* In AlphaPro, select '''Exchange & System''' -> '''Boards''' |
:* Change the port setting from ‘Audio program feed’ to ‘Default’ | :* Change the port setting from ‘Audio program feed’ to ‘Default’ | ||
:* Reset the exchange | :* Reset the exchange |
Revision as of 08:52, 13 August 2009
In the AlphaCom E7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.
- To set physical number 5 and/or 6 to be used as normal subscriber ports:
- Set jumpers 5 and 6 to pos 1-2
- In AlphaPro, select Exchange & System -> Boards
- Change the port setting from ‘Audio program feed’ to ‘Default’
- Reset the exchange