Difference between revisions of "Physical number 5 and 6 (AlphaCom E7)"
From Zenitel Wiki
Line 2: | Line 2: | ||
[[Image:ACE7 backplane.jpg|thumb|AlphaCom E7 backplane]] | [[Image:ACE7 backplane.jpg|thumb|AlphaCom E7 backplane]] | ||
* To set physical number 5 and/or 6 to be used as normal subscriber ports: | * To set physical number 5 and/or 6 to be used as normal subscriber ports: | ||
− | :* Set jumpers | + | :* Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. Jumpers P5 is for physical port 5, and jumpers P6 is for physical number 6. |
:* In AlphaPro, select '''Exchange & System''' -> '''Boards''' | :* In AlphaPro, select '''Exchange & System''' -> '''Boards''' | ||
:* Change the port setting from ‘Audio program feed’ to ‘Default’ | :* Change the port setting from ‘Audio program feed’ to ‘Default’ |
Revision as of 08:54, 13 August 2009
In the AlphaCom E7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.
- To set physical number 5 and/or 6 to be used as normal subscriber ports:
- Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. Jumpers P5 is for physical port 5, and jumpers P6 is for physical number 6.
- In AlphaPro, select Exchange & System -> Boards
- Change the port setting from ‘Audio program feed’ to ‘Default’
- Reset the exchange