In the AlphaCom E7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.

AlphaCom E7 backplane
  • To set physical number 5 and/or 6 to be used as normal subscriber ports:
  • Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. Jumpers P5 is for physical port 5, and jumpers P6 is for physical number 6.
  • In AlphaPro, select Exchange & System -> Boards
  • Change the port setting from ‘Audio program feed’ to ‘Default’
  • Reset the exchange