Actions

Difference between revisions of "Physical number 5 and 6 (AlphaCom E7)"

From Zenitel Wiki

Line 3: Line 3:
 
[[Image:Board Use default.png|thumb|left|Set physical number 5 and 6 to "Default"]]
 
[[Image:Board Use default.png|thumb|left|Set physical number 5 and 6 to "Default"]]
 
* To set physical number 5 and/or 6 to be used as normal subscriber ports:
 
* To set physical number 5 and/or 6 to be used as normal subscriber ports:
:* Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. Jumpers P5 is for physical port 5, and jumpers P6 is for physical number 6.
+
:* Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
 
:* In AlphaPro, select '''Exchange & System''' -> '''Boards'''
 
:* In AlphaPro, select '''Exchange & System''' -> '''Boards'''
 
:* Change the port setting from ‘Audio program feed’ to ‘Default’
 
:* Change the port setting from ‘Audio program feed’ to ‘Default’

Revision as of 08:59, 13 August 2009

In the AlphaCom E7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.

AlphaCom E7 backplane
Set physical number 5 and 6 to "Default"
  • To set physical number 5 and/or 6 to be used as normal subscriber ports:
  • Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
  • In AlphaPro, select Exchange & System -> Boards
  • Change the port setting from ‘Audio program feed’ to ‘Default’
  • Reset the exchange