Difference between revisions of "Physical number 5 and 6 (AlphaCom E7)"
From Zenitel Wiki
Line 1: | Line 1: | ||
In the AlphaCom E7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default. | In the AlphaCom E7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default. | ||
− | [[Image:ACE7 backplane.jpg|thumb|AlphaCom E7 backplane]] | + | [[Image:ACE7 backplane.jpg|thumb|300px|AlphaCom E7 backplane]] |
− | [[Image:Board Use default.png|thumb|left|Set physical number 5 and 6 to "Default"]] | + | [[Image:Board Use default.png|thumb|left|400px|Set physical number 5 and 6 to "Default"]] |
* To set physical number 5 and/or 6 to be used as normal subscriber ports: | * To set physical number 5 and/or 6 to be used as normal subscriber ports: | ||
:* Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6. | :* Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6. |
Revision as of 08:36, 11 November 2011
In the AlphaCom E7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.
- To set physical number 5 and/or 6 to be used as normal subscriber ports:
- Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
- In AlphaPro, select Exchange & System -> Boards
- Change the port setting from ‘Audio program feed’ to ‘Default’
- Reset the exchange