Physical number 5 and 6 (AlphaCom E7): Difference between revisions
From Zenitel Wiki
No edit summary |
No edit summary |
||
| Line 1: | Line 1: | ||
In the AlphaCom | In the AlphaCom XE7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default. | ||
[[Image:ACE7 backplane.jpg|thumb|300px|AlphaCom | [[Image:ACE7 backplane.jpg|thumb|300px|AlphaCom XE7 backplane]] | ||
[[Image:Board Use default.png|thumb|left|400px|Set "Port Use" for physical number 5 and 6 to "Default"]] | [[Image:Board Use default.png|thumb|left|400px|Set "Port Use" for physical number 5 and 6 to "Default"]] | ||
* To set physical number 5 and/or 6 to be used as normal subscriber ports: | * To set physical number 5 and/or 6 to be used as normal subscriber ports: | ||
Revision as of 14:34, 7 September 2015
In the AlphaCom XE7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.
- To set physical number 5 and/or 6 to be used as normal subscriber ports:
- Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
- In AlphaPro, select Exchange & System -> Boards
- Change the port setting from ‘Audio program feed’ to ‘Default’
- Reset the exchange