Actions

Difference between revisions of "Physical number 5 and 6 (AlphaCom E7)"

From Zenitel Wiki

Line 1: Line 1:
 
In the AlphaCom XE7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.  
 
In the AlphaCom XE7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.  
[[Image:ACE7 backplane.jpg|thumb|300px|AlphaCom XE7 backplane]]
+
 
[[Image:Board Use default.png|thumb|left|400px|Set "Port Use" for physical number 5 and 6 to "Default"]]
+
 
 
* To set physical number 5 and/or 6 to be used as normal subscriber ports:
 
* To set physical number 5 and/or 6 to be used as normal subscriber ports:
 
:* Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
 
:* Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
 +
[[Image:ACE7 backplane.jpg|thumb|400px|left|AlphaCom XE7 backplane]]
 +
<br style="clear:both;" />
 +
 
:* In AlphaPro, select '''Exchange & System''' -> '''Boards'''
 
:* In AlphaPro, select '''Exchange & System''' -> '''Boards'''
 
:* Change the port setting from ‘Audio program feed’ to ‘Default’
 
:* Change the port setting from ‘Audio program feed’ to ‘Default’
 
:* Reset the exchange
 
:* Reset the exchange
 +
 +
[[Image:Board Use default.png|thumb|left|400px|Set "Port Use" for physical number 5 and 6 to "Default"]]
 +
<br style="clear:both;" />
  
 
[[Category: Troubleshooting]]
 
[[Category: Troubleshooting]]
 
[[Category: AlphaCom Troubleshooting]]
 
[[Category: AlphaCom Troubleshooting]]
 
[[Category: Station Troubleshooting]]
 
[[Category: Station Troubleshooting]]

Revision as of 14:43, 7 September 2015

In the AlphaCom XE7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.


  • To set physical number 5 and/or 6 to be used as normal subscriber ports:
  • Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
AlphaCom XE7 backplane


  • In AlphaPro, select Exchange & System -> Boards
  • Change the port setting from ‘Audio program feed’ to ‘Default’
  • Reset the exchange
Set "Port Use" for physical number 5 and 6 to "Default"