Difference between revisions of "Physical number 5 and 6 (AlphaCom E7)"
From Zenitel Wiki
Line 2: | Line 2: | ||
− | * To | + | * To enable physical number 5 and/or 6 to be used for regular intercom stations: |
:* Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6. | :* Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6. | ||
[[Image:ACE7 backplane.jpg|thumb|400px|left|AlphaCom XE7 backplane]] | [[Image:ACE7 backplane.jpg|thumb|400px|left|AlphaCom XE7 backplane]] |
Revision as of 14:43, 7 September 2015
In the AlphaCom XE7 the physical numbers 5 and 6 on the first ASLT line board are enabled for program distribution by default.
- To enable physical number 5 and/or 6 to be used for regular intercom stations:
- Set jumpers P5 and/or P6 to position 1-2. There are five jumpers for P5, and five jumpers for P6. P5 is for physical port 5, and P6 is for physical number 6.
- In AlphaPro, select Exchange & System -> Boards
- Change the port setting from ‘Audio program feed’ to ‘Default’
- Reset the exchange