Revision as of 12:01, 25 February 2015
AMS is used to play prerecorded audio message to a single station.
Syntax
AMS <phys.no>
- <phys.no> = The physical number of the station (1-552)
= The index number of the audio message (1-80)
From software version 11.2.3.11:
AMS <phys.no><hvo>
- <hvo> Optional parameter "handset volume override". 1 = on, 0 = off. Default = 1
Examples
AMS 23 2 – Alarm message 2 (8192) to station 23 AMS 23 0 – Alarm message OFF to station 23 AMS 23 2 0 – Alarm message 2 (8192) to station 23, without volume override