Difference between revisions of "Wake-up call feature"
From Zenitel Wiki
(New page: '''75 FEAT_WAKE_UP''' {| border="1" !style="background:#ffdead;"|Param1 !style="background:#ffdead;"|Description |- | ?? || Wake-up call |- |colspan="2"|Order wake-up ringing at <selected ...) |
|||
Line 1: | Line 1: | ||
+ | {| | ||
+ | |- | ||
+ | |width="170pt"|'''Feature''': | ||
+ | | Disable RCI input | ||
+ | |- | ||
+ | |'''Default directory number''': || 7888 | ||
+ | |- | ||
+ | |'''Feature number''': || 69 | ||
+ | |-valign="top" | ||
+ | |'''Parameter 1''': || 0 (N/A) | ||
+ | |-valign="top" | ||
+ | |'''Description''': || Disable a [[RCI|Remote Control Input RCI]]. <br> | ||
+ | Procedure: Dial 7888 + RCI number.<br> | ||
+ | See also [[Enable alarm input feature|7889 - Enable RCI]] | ||
+ | |||
+ | |} | ||
+ | |||
'''75 FEAT_WAKE_UP''' | '''75 FEAT_WAKE_UP''' | ||
{| border="1" | {| border="1" |
Revision as of 20:59, 28 January 2008
Feature: | Disable RCI input |
Default directory number: | 7888 |
Feature number: | 69 |
Parameter 1: | 0 (N/A) |
Description: | Disable a Remote Control Input RCI. Procedure: Dial 7888 + RCI number. |
75 FEAT_WAKE_UP
Param1 | Description |
---|---|
?? | Wake-up call |
Order wake-up ringing at <selected time/date>.
Dial: <dir.no> Date defaults to tomorrow, can be set up to 10 months ahead. |